Descargar Imprimir esta página

Time Mode - Fluke EDDYTHERM 2x Manual De Instrucciones

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 77
 Press POWER to select the power level. Use the guidelines in
section 7.8 to determine the correct power setting.
 Press START/STOP to start the heater. The main display shows
the current temperature of the workpiece.
 When the selected temperature has been reached, the heater
demagnetises the workpiece, switches off, and generates an
acoustic signal for 10 seconds or until START/STOP is pressed.
 Press START/STOP to stop the heater.
 Always wear protective gloves and other appropriate protective
equipment when removing the hot workpiece to avoid the risk
of burning. The workpiece may also be removed using suitable
handling equipment.
 If the workpiece remains on the heater, the heater will start
again when the temperature of the workpiece drops 10°C
(18°F). Press START/STOP to stop the heater and demagnetise
the workpiece.
 The device is now ready to heat another workpiece with the
same settings.

7.4 Time mode

 If the main display shows °C or °F, press MODE to select TIME
MODE. The main display shows 't' in TIME MODE.
 Press UP or DOWN to adjust the time in steps of 0.1 minute.
 Press POWER to select the power level. Use the guidelines in
section 7.8 to determine the correct power setting.
 Press START/STOP to start the heater. The main display shows
the time that remains.
 When the time has elapsed, the heater demagnetises the
workpiece, switches off, and generates an acoustic signal for 10
seconds.
 Press START/STOP to turn the induction heater off.
 Always wear protective gloves and other appropriate protective
equipment when removing the hot workpiece to avoid the risk
of burning. The workpiece may also be removed using suitable
handling equipment.
 Remove the workpiece using proper handling equipment.
 The device is now ready to heat the next workpiece with the
same settings.
14

Publicidad

loading