5. Scope of delivery and operation

5.1. Scope of delivery

Before the first commissioning, the delivery must first be checked for completeness in
accordance with the scope of delivery below. If, contrary to expectations, parts are missing,
please report this immediately to your local Bona system consultant or contact our Service
Hotline on +49 (0) 180-42 66 283.
Scope of delivery Bona OptiSpread UX
Quantity
Part
1
Bona OptiSpread UX
1
battery charger (+mains connection)
2
18.8 V Li battery blocks
3
nozzles 1000 F [B10] (optional 1500F/G)
1
nozzle head
1
support stand
1
hook spanner
1
screwdriver PZ 1/80
1
screw set for nozzle assembly
1
spare parts list
1
transport bag
To open the tubular bags, we recommend using a pair of pliers, which are not included in
the scope of delivery.

5.2. Operation

5.2.1. Charging the battery

The battery blocks supplied are shipped from the factory with a low charge to avoid
potential problems. They must therefore be charged before use until the green LED on the
front of the charger lights up continuously.
When the charger is connected to the mains power, the red LED lights up. When inserting
the battery, the green LED flashes to indicate that the battery is being charged. If the green
LED lights up continuously, charging is connected.
A flashing red LED indicates that the battery is faulty. This could be because the battery
is hot, cold or faulty. Disconnect it from the charger and wait 30 minutes before trying to
charge the battery again.
10
Operating manual
Make sure that the power supply is suitable for the charger supplied. Also ensure that the
battery is correctly aligned and inserted into the charger as instructed.
Do not attempt to open batteries or the charger. They do not contain any repairable parts.
Once the battery is fully charged, the Bona OptiSpread UX battery can be used.

5.2.2. Filling/tubular bag change

To fill the Bona OptiSpread UX, as well as to change an emptied tubular bag, place the
machine on the supplied support stand. Secure the machine at the head end with the
clamping rubber.
1. Unscrew the nozzle head, which is fastened to the filling tube with a union nut and put it
to one side.
2. Remove the remaining emptied tubular bag
3. Unlock the toothed rack and pull it out again completely by the hook handle (fig. 1)
4. Insert the new tubular bag horizontally and remove the clip. When inserting, please make
sure that the bag does not kink (fig. 2, 3)
5. Screw the nozzle head back on, loosen the clamping rubber and take the machine off the
support stand. When placing the nozzles, make sure that the pointed end of the teeth
points upwards.
Note: If the charger does not charge the battery under normal conditions, please
contact the Bona service number listed.
Note: When charging for the first time, batteries do not charge completely.
Several cycles are required for a full charge.
Only charge the battery with the charger provided.
RED LIGHT – CHARGER IS SUPPLIED WITH POWER
FLASHING RED LIGHT – BATTERY IS HOT, COLD OR FAULTY
GREEN LIGHT – BATTERY IS FULLY CHARGED
FLASHING GREEN LIGHT – BATTERY IS BEING CHARGED
NEVER PLACE THE BONA OPTISPREAD UX ON THE TOOTHED RACK.
THIS CAN LEAD TO MALFUNCTIONS!!