FOR PROPER ELECTRICAL CONNECTIONS, CHECK
LOCAL BUILDING CODE. UNIT MUST BE INSTALLED BY
A QUALIFIED LICENSED ELECTRICIAN
1. Hold the Installation Template against the wall in the
desired location of the installed unit. Recommended
mounting height of the bottom of air-outlet is 40"
(1015mm) above finished floor.
2. Make sure line on template representing bottom of unit
mounting base is horizontal and located at the desired
height above floor.
NOTE: Surface-mounted electrical supply entry is located
in the lower right corner of the mounting base. Surface-
mounted supply
cable should be fitted in a conduit.
3. For brick, stone and concrete walls, drill four 0.315"
(8mm) holes to suit provided wall plugs 0.315" x 1-1/4"
(8 x 45mm) and screws #10 x 2" (4.8 x 50mm) long.
See template for wall plug and screw installation details.
For plaster or dry wall construction, provide concealed
backing to comply with local building codes and secure
with four #10 (4.8) round-head sheet-metal screws or
3/16" (5mm) toggle bolts (not furnished).
4. Fasten mounting base securely to wall.
WARNING: TURN ELECTRICAL POWER SUPPLY OFF
BEFORE MAKING ELECTRICAL CONNECTIONS. UNIT
MUST BE GROUNDED (EARTHED).
WARNING: TURN ELECTRICAL POWER SUPPLY OFF BEFORE MAKING ELECTRICAL CONNECTION.
FOR PROPER ELECTRICAL CONNECTIONS, CHECK LOCAL BUILDING CODE. UNIT MUST BE INSTALLED BY A
QUALIFIED LICENSED ELECTRICIAN
1. This appliance is intended for connection to fixed wiring. A fused means for disconnection in all poles must be
provided in the fixed wiring in accordance with the wiring rules.
2. Check that the electrical rating shown on the Hand Dryer (rating label) is compatible with the electrical supply.
WARNING: THIS PRODUCT MUST BE EARTHED.
3. Electrical installation and repair should be carried out by a qualified electrician in accordance with local codes and
regulations.
4. Maximum overall dimension of supply cable must be 9/16" (14mm) diameter.
5. Connect the ground / earth supply to the terminal marked,( ) the Live supply to the terminal marked (L) and the
Neutral supply to the terminal marked (N).
1. Turn electrical power supply on. Position hands under nozzle and unit should turn on for 20 seconds
(+6 seconds).
Installation of Mounting Base
Electrical Connection
Check Unit's Operation
Form No. 9100_ii Issued 1/25/22 © 2022 Bobrick Washroom Equipment, Inc.
8.00mm x 4
1
2.
2
3
A
B
x 2
1
2
3