English
– Max. water supply pressure (p in max.): 1 MPa
(10 bar)
– Max. water throughput (Q max.): 7.5 l/min
(450 l/h)
– Minimum water throughput (Q min.): 5.2 l/min
(310 l/h)
– Max. suction lift: 0.5 m
– Max. water temperature in pressure mode
(t in max): 40 °C
– Max. water temperature in suction mode:
20 °C
– sample inspection
– Length: 290 mm
– Width: 270 mm
– Height: 800 mm
– Length of high-pressure hose: 5 m
– Weight (m) with accessory attached: 7.5 kg
Versions from 220 V to 230 V / from 50 to 60 Hz
– Fuse (characteristic "C" or "K"): 10 A
– Power consumption: 1.7 kW
– Maximum permitted network impedance: 0.26
Ohm
– Protection class: II
– Degree of of electrical protection: IPX5
– Working pressure (p): 9 MPa (90 bar)
– Max. permissible pressure (p max.): 12 MPa
(120 bar)
– Max. water supply pressure (p in max.): 1 MPa
(10 bar)
– Max. water throughput (Q max.): 7.2 l/min
(430 l/h)
– Minimum water throughput (Q min.): 5.5 l/min
(330 l/h)
– Max. suction lift: 0.5 m
– Max. water temperature in pressure mode
(t in max): 40 °C
– Max. water temperature in suction mode:
20 °C
– sample inspection
– Length: 290 mm
– Width: 270 mm
– Height: 800 mm
– Length of high-pressure hose: 5 m
– Weight (m) with accessory attached:
7 kg to 7.5 kg
Parameters dependent on pressure have been
measured at an inlet pressure of 0.3 MPa (3
bar).
18.3
Extension Cords
If an extension cord is used, it must have a
ground wire and the wire gage of its conductors
must meet the following minimum requirements –
46
19 Spare Parts and Accessories
depending on the line voltage and length of the
extension cord:
If rated voltage on the rating label is 220V to
240V:
– Cord length up to 20 m: AWG 15 / 1.5 mm²
– Cord length 20 m up to 50 m: AWG 13 /
2.5 mm²
If rated voltage on the rating label is 100 V to
127 V:
– Cord length up to 10 m: AWG 14 / 2.0 mm²
– Cord length 10 m up to 30 m: AWG 12 /
3.5 mm²
18.4
Sound Values and Vibration
Values
The K-value for sound pressure levels is 2 dB(A).
K-value for sound power levels is 2 dB(A). The
K-value for vibration level is 2 m/s².
– Sound pressure level L
to EN 60335‑2‑79: 80 dB(A)
– Sound power level L
EN 60335-2-79: 91 dB(A)
– Vibration level a
measured according to
h
EN 60335‑2‑79, fan-jet nozzle: ≤ 2.5 m/s².
For information on compliance with Employers'
Vibration Directive 2002/44/EC see
www.stihl.com/vib.
18.5
REACH
REACH is an EC regulation and stands for the
Registration, Evaluation, Authorisation and
Restriction of Chemical substances.
For information on compliance with the REACH
regulation see www.stihl.com/reach.
19 Spare Parts and Accesso‐
ries
19.1
Spare parts and accessories
These symbols indicate original STIHL
spare parts and original STIHL acces‐
sories.
STIHL recommends the use of original STIHL
spare parts and accessories.
Despite ongoing market observation, STIHL is
unable to judge the reliability, safety and suitabil‐
ity of other manufacturers' spare parts and
accessories; accordingly, STIHL cannot warrant
for the use of those parts.
Original STIHL spare parts and original STIHL
accessories are available from STIHL dealers.
measured according
pA
measured according to
wA
0458-001-9821-B