Section 15
Tank Heating

15.1 Usage

In places where the Froth-Pak
ambient temperature is below 65°F (18°C), an external source to
heat the chemical in the tanks may be required .
Heating bands are available for both the 17 gallon and the
60 gallon tanks, through:
McMaster-Carr
www .mcmaster . c om
630-600-3600
The heater band McMaster model numbers are as follows:
17 gallon: 3545K42
60 gallon: 3545K44
Control boxes are available through:
Glas-Col Apparatus Company
711 Hulman Street, P . O . Box 2128
Terre Haute, IN 47802
812 - 235 - 6167
The model number for the control box is PL-312 .
During the initial start-up, the controls for the heater bands can
be set at 3 or 4 for two hours . However, for continuous operation,
"LO" would be the desired setting, unless extremely low tempera-
tures are experienced .
15.2 Installation Procedure – Tank Heater Band
1 . Wrap and clamp heater band around tank prior to
switching on .
2 . Pull on spring, at the same time hold end of heater against
the tank .
3 . Place a loop of the spring over the hook .
4 . The heater should not be clamped in dented areas of the tank .
5 . The heater must be in full contact with the tank and below
the level of the liquid while in operation .
6 . DO NOT bend the heater sharply as this may cause internal
damage to the heating element .
7 . DO NOT use outside insulation .
NOTE: Heaters are available for other tank heating operations, refer to
Electro-Flex Heat, Inc .
Refill System is used where the
15.3 POWERBLANKET
warming equipment
®
POWERBLANKET
warming equipment
®
also keeps your jobs on schedule during
the colder months, delivering a barrier
of insulated heat to the spray foam Powerblanket creates an
optimal application environment .
For more information, call Customer Service at 877-398-7407 .
To order, call 801-456-8013 and refer to the item numbers
below:
• DuPont-17 (17-gallon tank heater)
• DuPont-27 (27-gallon tank heater)
• DuPont-60 (60-gallon tank heater)
• DuPont-620 (620& 650 -bf single-component cylinder heater)
• DuPont-200 (200 & 210 -bf A & B disposable box heater)
• DuPont-55RR (Rapid Ramp 55-gallon drum heater)
• DuPont-55PRO (Pro series 55-gallon drum heater and
thermostatic controller)
• DuPont-GHT (Digital thermostatic controller)

15.4 Glas-Col Power Control Description and Operation

The Glas-Col Minitrol is a manually adjusted power control of
percentage timer design . Minitrol is designed to proportion full
output power 5 .5% to 100% of time depending on the dial set-
ting . The "Off " position positively breaks both sides of the line .
The control can be used on any non-inductive fused resistance
load up to 15 amps and 120 volts . Smaller fuses may be used for
protection of very small loads . Simply plug device into a 3-wire
outlet of the control and insert plug of Minitrol cord into a wall
receptacle . The pilot light is connected across the output side
of the control and indicates power to the load . Minitrol's opera-
tion and control is adjusted by the operator and does not utilize
a sensing element . After a desired temperature has been
determined on the initial run, a simple resetting of the dial
offers control for repeat operations .
Dial Setting
Off
Lo
4
6
Hi
This control effectively regulates heating mantles, tapes and
cords . Minitrol may also be used for small furnaces or ovens,
hot plates, dies or other applications requiring infinite control .
The control should not be exposed to ambient temperatures
above 125°F (52°C) .
Percent of time on
0
5 .5 (approx .)
35 (approx .)
52 (approx)
100