5. PREPARATIONS BEFORE USE
CAUTION! Set the controller output mode to "OFF" (see section 6.4) to ensure drivers will not be
accidentally activated during the controller setup. After this, it is safe to either connect the drivers to the
main power supply or insert the signal cable from the drivers into the controller.
Note: After 60 seconds of inactivity the controller interface will return to the main menu.
Note: To leave any screen without saving changes, press the BACK key.
Note: More functions can be accessed by clicking the UP key.
1. Ensure you have carried out all applicable steps from section 4.
2. Set the controller output mode to "OFF. "
3. Plug the driver into the main power supply.
4. Verify your controller is ready for use by performing the actions described in this section.
5.1 Localizing the Controller
2. Setting the time.
Note: The controller can only be set to a 24-hour clock.
a. Press ENTER, the controller menu will open.
b. Press the UP/DOWN keys to locate "system time" and press ENTER. The System Time Screen
(Figure 7) will open. The "hour" indication (Figure 7A) will start blinking.
c. Press the UP/DOWN keys to select the correct hour.
Press ENTER to confirm.
d. Use the same procedure to set the minutes (Figure 7B).
Press ENTER to confirm your choice and return to the
controller menu.
3. Switch temperature units between °C and °F.
Note: The default temperature is set to °C.
a. Press ENTER, the controller menu will open.
b. Press the UP/DOWN keys to locate "temp units" and
press ENTER. The Temperature Units Screen will open.
c. Press the UP/DOWN keys to switch between °C and °F. Press ENTER to confirm your choice and
return to the controller menu.
6. PROGRAMMING AND USING THE CONTROLLER
CAUTION! Set the controllers output mode to "OFF" (see section 6.4) to ensure no drivers will be
accidentally activated during the controller setup.
Follow the actions listed below to quickly start using the controller.
1. Set the controller output level. (see section 6.1)
2. Program a light cycle. (see section 6.2)
3. Set the safety shutdown temperature. (see section 6.4)
4. Activate the auto mode on the controller. (see section 6.4)
6.1 Adjust Driver Output to Change Light Intensity
The controller can set the output of a driver between 10% and 100%. Adjusting this driver output enables
the user to change the light intensity in the climate room.
1. Press the DIMMING key. The Output Level Screen opens.
2. Press the UP/DOWN keys to set the driver output between 10% and 100%. Refer to the LED grow light
system installation instructions to reference wattage at a particular percentage.
3. Press ENTER to confirm your choice.
Note: The output level can also be found in the main menu.