Descargar Imprimir esta página

gefran 1600P Manual De Uso página 23

Programador / regulador

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 66
Ser
Serial communication
Unit identification code for serial
(ode
communication (if enabled)
[see "hrd.1" in Hrd]
38
Serial interface
ser. p
protocol
CENCAL, MODBUS
39
InP
Input settings
sp. t y
Setpoint type:
LOC/REM, Select type
of remote setpoint
[0...7]
44
type
Probe type, signal, enable custom linearization,
45
PROBE: TC (SEnS=0)
tYPE Probe type
0
J (Fe-CuNi)
1
J (Fe-CuNi)
2
K (NiCr-Ni)
3
K (NiCr-Ni)
4
R (Pt13Rh - Pt)
5
R (Pt13Rh - Pt)
6
S (Pt10Rh - Pt)
7
S (Pt10Rh - Pt)
8
T (Cu-CuNi)
9
T (Cu-CuNi)
10
B (Pt30Rh - Pt6Rh)
11
B (Pt30Rh - Pt6Rh)
12
E (NiCr-CuNi)
13
E (NiCr-CuNi)
14
N (NiCrSi-NiSi)
15
N (NiCrSi-NiSi)
16
(Ni - Ni18Mo)
17
(Ni - Ni18Mo)
18
L - GOST (NiCr-CuNi)
19
L - GOST (NiCr-CuNi)
20
TC
21
TC
PROBE: RTD 3 wires (SEnS=1)
tYPE Probe type
0
PT100
1
PT100
2
JPT100 (JIS C 1609/81)
3
JPT100 (JIS C 1609/81)
4
RTD
5
RTD
PROBE: PTC (SEnS=2)
tYPE Probe type
0
PTC 990Ω
1
PTC 990Ω
2
PTC 990Ω
3
PTC 990Ω
PROBE: VOLTAGE 50mV (SEnS=3)
tYPE Signal type
0
0...50mV
1
0...50mV
2
10...50mV
3
10...50mV
0 ... 9999
SEr.P Serial protocol
0
CENCAL GEFRAN
1
MODBUS RTU
SP.tY
Type of
remote setpoint
0
analogue (InP.2)
1
analogue (InP.2)
2
digital
(from serial line)
3
digital
(from serial line)
and main input scale
Scale
Scale range max.
(C/F)
without decimal point
C
0 / 1000
F
32 / 1832
C
0 / 1300
F
32 / 2372
C
0 / 1750
F
32 / 3182
C
0 / 1750
F
32 / 3182
C
-200 / 400
F
-328 / 752
C
44 / 1800
F
111 / 3272
C
-100 / 750
F
-148 / 1382
C
0 / 1300
F
32 / 2372
C
0 / 1100
F
32 / 2012
C
0 / 600
F
32 / 1112
C
Custom scale
F
Custom scale
Scale
Scale range max.
(C/F)
without decimal point
C
-200 / 850
F
-328 / 1562
C
-200 / 600
F
-328 / 1112
C
Custom scale
F
Custom scale
(on request, instead of RTD 3 wires)
Scale
Scale range max.
Scale range max.
(C/F)
without decimal point
with decimal point
C
-55 ... 120
-55.0 ... 120.0
F
-67 ... 248
-67.0 ... 248.0
C
Custom scale
F
Custom scale
Scale
Max. scale range
linear
-1999 / 9999
custom linear
see table 32 values in Lin
linear
-1999 / 9999
custom linear
see table 32 values in Lin
• Ser
bavd
40
par
-
101
• InP
Absolute
Relative
absolute
relative to
local setpoint
absolute
relative to
local setpoint
Scale range max.
PROBE: CURRENT 20mA or TRANSMITTER (SEnS=4)
with decimal point
0.0 / 999.9
tYPE Signal type
32.0 / 999.9
0
0...20mA
0.0 / 999.9
1
0...20mA
32.0 / 999.9
2
4...20mA
Not available
3
4...20mA
Not available
Not available
PROBE: CURRENT 10V or TRANSMITTER (SEnS=5)
Not available
tYPE Signal type
-199.9 / 400.0
0
0...10V
-199.9 / 752.0
1
0...10V
Not available
2
2...10V
Not available
3
2...10V
-100.0 / 750.0
-148.0 / 999.9
PROBE: CUSTOM 10V (SEnS=6)
0.0 / 999.9
32.0 / 999.9
tYPE
0.0 / 999.9
0
32.0 / 999.9
0.0 / 600.0
1
32.0 / 999.9
(*)
(*)
PROBE: CUSTOM 50mV, 20mA (SEnS=7)
tYPE
Signal type
0
Scale range max.
1
with decimal point
-199.9 / 850.0
-199.9 / 999.9
(*) Linearization and scale limit settings (with or without decimal point) are
-199.9 / 600.0
selectable from PC via serial line
-199.9 / 999.9
(*)
(*)
(*)
(*)
23
Selects
Baudrate
bAud Baudrate
CENCAL Interface
0
1200
485 / 232
1
2400
485 / 232
2
4800
485 / 232
3
9600
485 / 232
4
19200
485 / 232
_PAr
Parity selection
0
(MODBUS only)
1
2
Scale
Scale range max.
linear
-1999 / 9999
custom linear
see table 32 values in Lin
linear
-1999 / 9999
custom linear
see table 32 values in Lin
Scal
Scale range max.
lineare
-1999 / 9999
custom linear
see table 32 values in Lin
linear
-1999 / 9999
custom linear
see table 32 values in Lin
Signal type
Scale
Scale range max.
Custom 0...10V
linear
-1999 / 9999
Custom 0...10V
custom linear
see table 32
values in Lin
Scale
Scale range max.
Custom
linear
-1999 / 9999
Custom
custom linear
see table 32
values in Lin
MODBUS Interface
485
485
485
485
485
Parity
No parity
Odd
Even

Publicidad

loading

Este manual también es adecuado para:

1800p