Commissioning/start-up
NOTE
Never connect the pump to a dimmer. This will destroy the pump
NOTE
Never allow the pump to run dry. Otherwise the pump will be destroyed.
Only operate the pump when it is submerged or flooded.
A brand-new pump will only reach its maximum capacity after several hours of operation.
Switching ON/OFF
• Switching on: Plug the power plug into the outlet.
– The unit switches on immediately.
• Switching off: Pull the power plug from the outlet.
Environmental Function Control (EFC)
When started up, the pump automatically performs a pre-programmed self-test (Environmental
Function Control (EFC)). The pump detects if it is running dry / blocked or submerged. The pump
turns off automatically after 60 to 120 seconds if it runs dry/is blocked. In the event of a mal-
function, disconnect the power supply and "flood the pump" or remove the obstacle. Afterwards,
the unit can be restarted.
Dynamic Function
• Slide the switch.
– ON: The function is activated.
– OFF: The function is deactivated.
NOTE
When Dynamic Function is activated, the EFC (Environmental Function Control) function is re-
stricted.
The unit is not protected from running dry.
16