Installation Instructions
• Ensure that the Matrix console is positioned on a secure level surface.
• Position the remote power supply unit in a convenient position below or behind the Matrix. The power supply must be located
on a hard surface and must remain upright so that it stands on its rubber feet.
• The power supply is convection cooled and sufficient space must be allowed for ventilation. A minimum of 200mm clearance
must be maintained both in front of and behind the unit.
The PSU unit must not be left in a position where it may become accidentally covered – such as by items of clothing or
paper – as this could constitute a fire risk.
• Confirm that the PSU unit is switched off before connecting the DC input lead.
• Connect the captive cable attached to the PSU to the input plug on the rear of the Matrix console.
The 12-pin connector is keyed so that it can only be inserted in one position – the rectangular key
on the free socket should be in the uppermost position.
• Push the connector inwards and, at the same time, rotate the silver locking ring 180° clockwise until
a click is heard. If correctly located, the locking ring should not easily rotate anticlockwise.
• Multiple power cords may be supplied with this unit – use only the power cord appropriate to your
local power wiring. Alternative power cords may be used if rated 2.5A or above and fitted with a 3-pin
IEC320 connector.
• Ensure that no strain is placed on the cables connecting to this apparatus. Ensure also that such cables are not placed where
they can be stepped on, pulled or tripped over.
Where the supply of mains power is provided from an uninterruptable source (UPS) the output waveform of the UPS
equipment must be of the sinusoidal variety. Switched or stepped output waveforms may cause damage to the console
power supply so must not be used.
EN
DE
ES
Key
FR
IT
DC Power Inlet
JP
5