Descargar Imprimir esta página

Control Panel; Maintenance Operations - POOLSTYLE SSCmini Manual Del Producto

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 10
5. Operating instructions
To achieve the correct installa�on, please follow the recommenda�ons listed below:
• Salt must be added into the pool before turning on the system. The SSCmini system must be turned off.
Wait un�l the salt is dissolved by running the filtering pump and placing the 6-way valve in recircula�on
mode.
• Adding salt in various �me and places makes easier for the salt to get dissolved.
• The main chemical parameters should be kept around the values appearing in the sec�on 2.Main features.
• Not maintaining these chemical values may:
- Harm and reduce the cell's life�me.
- Inac�vate chlorine effec�veness.
- Deteriorate the pool components.
• The water balance and a good opera�on environment must be assured so as to ensure a safe pool.
• In case of extreme hot weather or high bather load, it is recommended to increase the output power of the
SSCmini system or to add solid/liquid chlorine.

Control Panel

LEDs
1. Low cell life: The cell reached the end of its expected
life and must be replaced.
2. No Flow: there is no water flow throughout the cell.
3. General alarm: Refer to the sec�on 7.Troubleshoo�ng
4. Stand-by mode: The unit is not producing.
5. Normal opera�on: The unit is producing.
6. Superchlorina�on: The unit is producing during 24
hours con�nuously
9. Workschedule (produc�on): Each LED represents 6 min of chlorine produc�on. I.e.: 3 LEDs equals to 18
min, 4 LEDs equals to 24 min, and so forth.
Buttons
7. Superchlorina�on: produces 24 hours con�nuously.
8. Work schedule control: Raises(+) or lowers(-) the producing �me reflected on the workschedule LEDs.

6. Maintenance operations

• In regard of water hardness, the cell must be checked within different periods of �me so as to avoid excessi-
ve build-up scaling.
• As said in 5.Opera�on instruc�ons, it is mandatory to keep the chemical balance in a specific range. Not
doing so, the SSC Mini warranty cell could become void.
• In order to clean the cell, proceed as follows:
1. Disconnect the control unit.
2. Remove the cell from its housing a�er having drained the pipeline regarding to the salt chlorinator.
3. Rinse with fresh water the cell so as to remove any debris or other par�cle.
4. A�er having considered the safety instruc�ons men�oned on 1.Safety warnings, mix 1 part of
muria�c acid with 4 of fresh water in a bucket. Always add acid to the water, never backwards.
5. Introduce the cell into this solu�on. Repeat a�er having rinsed with fresh water. Do not scrub with
a metal brush.
6. A�erwards, rinse the cell with fresh water and assemble it again.
7. Before turning on again the cell, allow the cell housing to be filled with water.
• A very high water hardness may cause excessive scaling. To avoid that, drain some water and refill with
so�ened water.
• When backwashing the filter, disconnect the control unit in order not to produce chlorine without being
evacuated out of the cell housing. Do the same in recirculate and waste valve posi�on.