4.2
FLEXIBLE INDUCTOR
The flexible coil is used for releasing axle mounts, jammed sensors, ball joints, etc., where socket
coils cannot be used.
Correct procedure:
1. Connect one end of the coil to the coil holder and secure it with the lock screw.
2. Wrap the loose end of the conductor around the part to be heated. Make approximately 2-4
spirals.
3. Connect other, loose end of the coil to the coil holder and secure it with the screw.
4. Press the button to active heating.
5. Once the heating is completed, release one end of the coil and unwind it from the heated
material.
REMARK: The flexible inductor can be used for heating large nuts, exhaust pipes, bolts, axle parts,
shafts, etc.
CAUTION: Use original heating inductors only. If non-original accessories are used, the device
manufacturer is not liable for any damage due to device use. Use of a non-original inductor is
considered use in contravention of the Instruction Manual.