Descargar Imprimir esta página

Installation; Display Instrument; Connections - Vetus SENSORD Manual De Manejo Y Instrucciones De Instalación

Ocultar thumbs Ver también para SENSORD:

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 98
3

Installation

3.1

Display instrument

See Chapter 8 for the main dimensions.
Cut holes in the instrument panel or a bulk-
head using the template supplied. Fit the
display instrument using the 4 threaded
studs and nuts supplied. Make sure that the
packing is positioned correctly between the
instrument and the panel or bulkhead.
36
090430.01
3.2

Connections

3.2.1 Power supply
The instrument is suitable for both 12 and 24
Volt direct current.
Connect the power supply as shown in the
wiring diagram, see Chapter 6.
3.2.2 Background lighting
The background lighting can be switched
on and off by an external switch (dashboard
lighting). The function 'Light' must then be
set to 'Automatic' , see 2.4.6 'Setting the back-
ground lighting' .
3.2.3 Alarm outputs
External warnings, such as a light or a buzzer,
can be connected to the alarm outputs.
If these devices use more than 200 mA con-
nect a small relay in between.
3.2.4 Sensors
Fit the sensors in the tanks as described in the
instructions supplied with the sensor.
Each sensor has a cable (about 1.5 m ) with an
RJ45 connector.
Connect the sensors to the display instru-
ment and to each other as shown in the in-
stallation examples, see Chapter 7.
Use a patch cable*) and a double RJ45 cou-
pling piece to extend the cable to the sensor.
2 sensors can be connected directly to the
instrument.
NB: there is no difference between the two
connections!
Use the splitters and connection cables sup-
plied if more than 2 sensors have to be con-
nected.
3.2.5 Subsidiary instrument
Connect a subsidiary instrument directly to
Ultrasonic tank management system

Publicidad

loading