Normal issue and solution
Item
Issue
Indicator light
1
doesn't work,
jug doesn't
work
Jug ceases to
2
work after
starting
operation
Motor doesn't
3
work
4
No heating
Charring
5
Indicator
6
flashes
Reason
1.Plug is not inserted
properly.
2.Jug and power base
has poor contact.
3.No power in the jack
4. Problem with
components
1.Jug temperature is
too high
2.Jug damaged with
immersion in water
1. Jug is not cleaned
in good time after
use, milk locks the
mechanism.
2.Motor damage
1.Machine damage
1.The amount of milk
is not appropriate
2.Jug is reused
without cleaning
3.The actual voltage
is much lower than
the rated voltage
1.The heating tube is
overheated, so as
the machine is under
the condition of
over-temperature
protection
2.Operate without
anything in it,
temperature sensor is
damaged.
-09-
Solution
Re-insert
Remove the jug
Check the
electric circuit
Repair
Rinse cold water
inside the jug to
reduce temperature
Repair
Clean and move the
whisk of motor by
hand to loosen it.
Repair
Repair
Use the amount of
milk according to
the scale inside the
jug
Cleaning the jug
after each use
Check the voltage
indicated on the
name-plate and
use the appropriate
voltage
Unplug the power
cord and let it to
cool down.
Repair