Descargar Imprimir esta página

Fein AFMT12 Instrucciones De Uso página 12

Ocultar thumbs Ver también para AFMT12:

Publicidad

Idiomas disponibles

Idiomas disponibles

All manuals and user guides at all-guides.com
OBJ_BUCH-0000000180-001.book Page 12 Wednesday, April 15, 2015 8:23 AM
en
12
Assembly instructions.
Before mounting or replacing application tools or accessories, remove the bat-
WARNING
tery. This preventive safety measure rules out the danger of injuries through
accidental starting of the power tool.
For all work or when changing application tools, always wear protective gloves.
CAUTION
Danger of injury from the sharp edges of the application tools. Application
tools can become very hot while working. Danger of burns!
Removing and charging the battery
(figure 2).
Prior to the first charging procedure,
read the operating instructions of the
battery charger.
Charge the battery completely before
putting into operation for the first time.
Release the battery by pressing the battery
unlocking button and pull the battery out of the
handle. Do not exert any force when doing this.
Connect the battery charger to a socket out-
let, slide the battery onto the battery charger
and charge the battery. After the charging
process is over, insert the battery into the
power tool and pull the plug of the battery
charger out of the socket outlet.
A new battery does not reach its full capacity
until after several charging and discharging
procedures.
Changing the tool (AFMT12) (figure 3).
Possible overloading of the vibration damp-
ing with especially heavy accessories!
When using the large round sanding plate
(No. 63806195020, Ø115 mm) or the clean-
ing kit for tile joints (No. 63719011020), the
damping system can be subject to overload
due to the heavy weight of the accessories.
This becomes apparent through unpleasant
and very intense vibration of the machine.
Corrective action: Reduce the speed of the
machine to electronic level 2.
Due to the then possibly reduced working prog-
ress, the machine is only suitable to a limited
extent for above mentioned accessories.
The application tool can be offset in 45° steps
and fastened in the most favorable working
position.
Screw out the fastening element.
Clean the tool holder, the application tool and
the fastening element.
Fig. 2
Battery-Unlocking
button
Battery
Insert the application tool accurately into the
star-shaped tool holder. Pay attention that the
application tool is mounted flush.
Screw in the fastening element to the stop.
Fig. 3
Fastening element
Application tool
Tool holder

Publicidad

loading

Este manual también es adecuado para:

Afmt12q