40/44
Maintenance and repair
1.
Open the Liftgate (E).
Please note:
1
) Secure the open Liftgate
against folding down!
2.
Disassemble the holder.
3.
Detach and replace the
gas pressure spring (B);
(see page 22).
Bosch Rexroth AG, MIT: Liftgate, 3 842 358 734/2015-01
10.3.1
Replacing the gas pressure springs
2
SW6
M
=18 Nm
D
B
3
SW6
M
=18 Nm
D
Fig. 21:
Replacing the gas pressure springs
)
1
E
1
358 734-14