Installation
Electrical connection
WARNING
ELECTRICAL SHOCK HAZARD. DISCONNECT POWER
BEFORE SERVICING. REPLACE ALL PARTS AND PANELS
BEFORE OPERATING. FAILURE TO DO SO CAN RESULT IN
DEATH OR ELECTRICAL SHOCK.
1.
Run 3 wires - black, white, and green - according
to the National Electrical Code and local codes and
ordinances, in ¹⁄₂" conduit from the service panel to
the terminal box.
B
C
A
A. White wires
B. Black wires
C. UL listed wire connectors
D. Green, bare or yellow/
green wires
18
ENGLISH
D
E
F
E. Home power supply
F. UL listed or CSA
approved ¹⁄₂" (1.3 cm)
strain relief
WARNING
ELECTRICALLY GROUND THE FAN. CONNECT THE
GROUND WIRE TO THE GREEN AND YELLOW GROUND
WIRES IN THE TERMINAL BOX. FAILURE TO DO SO CAN
RESULT IN DEATH OR ELECTRICAL SHOCK.
2. Use UL listed wire connectors and connect black
wires (B) together.
3. Use UL listed wire connectors and connect white
wires (A) together.
4. Connect green (or bare) ground wire from home
power supply to the green/yellow ground wire (D) in
terminal box using UL listed wire connectors.
5. Close and secure the terminal box cover.