Commands
Menu item
Description
[EN]
[DE]
Detection time
The minimum detection time in the
44
user detection range is set so that
[DetectT]
users can be detected as a standing or
[VerweilZ]
seated user. The detection time is only
relevant when automatic flush
actuation is activated.
Flush delay
Once the user has left the user
45
detection range, a flush is not actuated
[DelayTime]
until the set time has elapsed. The
[Spülverzö]
flush delay is only relevant when
automatic flush actuation is activated.
Flush time for the interval flush
46
[HygFlshT]
The function of the interval flush is
[HygFlshT]
determined by menu item 34.
Sensor for detection range
The detection range of the sensors can
be tested using the [Test detection
range] (menu item 22) function. The
active sensor is selected here.
• User recognition: The sensor for the
user recognition detection range is
47
activated. LED lights up = user
[SensorSel]
detected.
[SensorSel]
• Manual flush actuation: The sensor
for the manual flush detection range
is activated. LED lights up = hand
detected.
• Proximity detection: The sensor for
the proximity detection range is
activated. LED lights up = user
movement in the detection range.
9007203771121035 © 04-2022
970.755.00.0(00)
Application
• To prevent flushes
due to unintentional
entry of a person into
the user detection
range
–
–
• To check the user
recognition
Value
Factory
setting
1–60 s
7 s
1–15 s
3 s
1–200 s
5 s
[0] = User
recognition
[1] = Manual
[0]
flush actuation
[2] = Proximity
detection
4 / 4
EN
33