Descargar Imprimir esta página

Heating Priority Wiring For Monophasic Pump - Hayward 81504 Manual De Instalación E Instrucciones

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 64
6. APPENDIX (continued)

6.2 Heating priority wiring for monophasic pump

Dry contact 16 A max
K2
Power supply
230V
/ 50Hz
Monophasic pump
Terminals 1 and 2 deliver a potential-free dry contact,
230V
/ 50 Hz, no polarity.
Wire terminals 1 and 2 as indicated in the diagram
above, to activate the operation of the filtration pump
in 2-minute cycles each hour if the temperature of the
pool is lower than the set point.
Never connect the power supply of the filtration
pump directly to terminals 1 and 2.
20

Publicidad

loading

Este manual también es adecuado para:

81514815248153481544