Descargar Imprimir esta página

Cleaning & Servicing - Delabie TEMPOMIX NT 795 Manual Del Usuario

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 18
• Sizing the pipes correctly will avoid problems of pressure loss and unwanted noise.
• Protect the installation with filters, water hammer absorbers and pressure reducers to reduce the
frequency of maintenance. (Recommended pressure: 1 - 5 bar).
• Install stopcocks close to the mixer to facilitate maintenance.
• The pipework, stopcocks, mixers and all sanitary ware must be checked regularly, and at least once a
year.
CLEANING & SERVICING
• Cleaning chrome:
Do not use abrasive, chlorine or any other acid-based cleaning products. Clean with soapy water using a
cloth or sponge.
• Frost protection:
Drain the pipes and operate the mixer several times to drain any remaining water. If the installation
remains unused for a period of time we recommend removing the cartridge mechanism storing it in
the shade at room temperature.
MAINTENANCE
To remove the mechanism (fig.
• Remove the central cap
• Unscrew the blocking screw with a screwdriver and remove the push-button control
• Partly unscrew the 3 cartridge-securing screws
raise the mechanism.
• Shut-off the hot and cold water supply using the stopcocks.
• Unscrew the 3 cartridge-securing screws
• Remove the mechanism by hand.
Impurities in the pipework may cause the valve to malfunction:
Inaccurate or continuous flow (fig.
• Clean the inside of the timing chamber
metallic pointer.
• Check the condition of the piston lip seal JN29
Constant dripping or a trickle of water (fig.
• Check the condition of the O ring JR2
Problems in achieving the correct mixed water temperature:
• Balance the water pressure HW/CW ( P < 1 bar)
• Check that there are no impurities on the non-return valves
• The non-return valves should be checked at least once a year.
NB: The joints between the stainless steel wall plate and the wall, and between the wall plate and the
body of the mixer, should be checked at least once a year to ensure that they are watertight. Check
more frequently if required, and replace as necessary.
For Delabie UK Ltd market only: Tel. +44 (0)1491 824 449 email: technical@delabie.co.uk
For all other markets: Tel. +33 (0)3 22 60 22 74 email: sav@delabie.fr
The most recent version of this installation guide is available on: www.delabie.com
):
using a pair of circlip pliers.
completely and remove the locking cap
):
using a dry cloth and the calibrated groove
):
and the washer JR6 bis
After Sales Care and Technical Support:
for 4 turns using a screwdriver. The water pressure will
, and the O ring JR2
.
(figs.
,
by hand.
+
by hand.
with a non-
.
).

Publicidad

loading