Descargar Imprimir esta página

geberit SIGMA80 Instructions De Montage página 52

Ocultar thumbs Ver también para SIGMA80:

Publicidad

EN
Menu item
Functions
[Interval flush]
[Power-on flush]
[Preflush]
[Automatic flush]
44
Description
Activate the interval flush
• User-controlled: A flush is
actuated at the end of the [flush
interval], whereby the flush
interval is restarted with every
use. The flush time is
determined by the [flush time]
value.
• Interval-controlled: A flush is
actuated at the end of the [flush
interval], regardless of the
number of uses. The flush time
is determined by the [flush time]
value.
• Difference flush: A flush is
actuated at the end of the [flush
interval], regardless of the
number of uses. If flushes have
already been performed within
the [flush interval], the postflush
only makes up the difference in
[flush time].
[Flush time]
[Flush interval]
[Flush volume]
The flush volume for the interval
flush is calculated from the [flush
time] above and the [flush volume
settings].
A flush is actuated after switching
on the mains voltage.
A partial flush is actuated when a
user is detected.
A flush is actuated automatically
when the user steps back from the
toilet. Manual flush actuation is no
longer necessary.
Application
• To fill the trap in the
case of low user
frequencies
• To flush out standing
water in the pipe
(hygiene function – to
prevent stagnation)
• Flush volume display
• To perform central flush
actuation
• To confirm a function
• To wet the WC ceramic
appliance before use to
avoid deposits
• Hygiene – There is no
need to touch the
actuator plate.
Value
Factory
setting
[Off], [User-
controlled],
[Interval-
[Off]
controlled],
[Difference
flush]
1–200 s
5 s
1–168 h
24 h
On/Off
Off
On/Off
Off
On/Off
On
2 / 5
9753440651 © 04-2022
970.779.00.0(00)

Publicidad

loading