Additional requirements for outdoor installation
● Make sure to set up the spa on a firm, level, and smooth surface that is strong enough to support the full
weight of the filled spa and the number of maximum occupants.
● Do not set up the spa on grass or directly on the ground, as this increases the amount of debris entering the
spa and can damage the spa floor.
● Do not leave the spa tub exposed to direct sun light for long timespan.
● Always keep the manometer on yellow section when using the spa at a temperature higher than 20°C
(68°F) or exposed to sunlight for a short time.
● Do not install or use the spa outdoor at a temperature lower than 4°C (39°F). Do not use the spa when the
water inside the circulation system, the pump, and the pipes is frozen. Put a Heat Preservation Mat in
between the spa bottom and the ground to prevent heat loss from the bottom of the spa and to provide
better heat retention.
PRCD Testing
Risk of electric shock: This product is provided with a PRCD located at the end of the power cord. The
PRCD must be tested before each use. Do not use the spa if the PRCD does not function properly.
Disconnect the power cord until the fault has been identified and corrected. Contact a licensed electrician to
correct the fault. There are no serviceable parts inside the PRCD. Opening the PRCD will void the warranty.
1. Plug the machine into the mains.
2. Press the RESET button on the PRCD. The indicator turns red.
3. Press the TEST button on the PRCD. The red color shown on the indicator should disappear. Otherwise the
PRCD is faulty. Do not use the spa if the spa is faulty. Contact a qualified electrician to correct the fault.
4. Press the RESET button on the PRCD again. The indicator should turn red. If yes, the spa is ready for use.
1.
√
Spa Control Unit Connected to External Equipotential Bonding Conductors
A qualified electrician shall wire the spa control unit to the household equipotential terminal using a minimum
1.5mm² solid copper conductor.
!
PRCD doesn't
work on faulty
sockets or plug
boards.
WARNING
2.
RESET
RESET
TEST
Indicator
12
3.
RESET
TEST
TEST