Tool use
read section titled "safety Warnings" before using tool.
TO lOaD: (cliPPeD HeaD)
➀ Insert strip of nails into rear of
magazine
➁ Pull feeder shoe back.
1
2
uNlOaDiNg THe TOOl:
Push Tab on feeder shoe to release feeder from strip. Pull fastener strip out past sheet metal nail detainer.
Do not load with workpiece contact (safety element) or trigger depressed.
Use only genuine SENCO fasteners (see Fastener Specifications).
actuation system:
With a contact-actuation ("Dual-action") trigger, fasteners can be driven two ways:
2
1
1
2
2
1
read the "customer satisfaction and safety reminder" (cssr) in the tool and fastener boxes for safety infor-
mation regarding the contact-actuation and sequential trigger modes. under certain conditions, the sequential
trigger mode may reduce the possibility of injury to you or to others working with you.
TO lOaD: (Full rOuND HeaD)
Dual-mode loading (Two methods to load)
Nails First
➀ Insert strip of nails into the rear of the magazine.
➁ Pull feeder shoe back beyond the end of the strip of nails and release.
OR
Feeder shoe First
➀ Insert strip of nails into the rear of the magazine.
➁ Pull feeder shoe all the way back until latch at rear of magazine locks.
③ Push down on silver latch at rear of the magazine to release feeder shoe.
The First Way:
➀ Press the workpiece contact (safety element) against the work surface.
➁ Pull the trigger and the fastener is driven.
The second Way:
➀ Pull and hold trigger.
➁ Depress workpiece contact element against work surface and drive a fastener. Each time you
push the workpiece contact (safety element) against the work surface, a fastener is driven.
This mode of operation is preferred when you desire high production, and rapid fastener place-
ment.
With a sequential actuation (restrictive) trigger, fasteners can only be driven one way:
➀ Press the workpiece contact (safety element) against the work surface.
➁ Pull the trigger.
This mode of operation is helpful when you require precise fastener placement.
2
1
10
3