Order
Code
number
3.3
T4HMAX
3.4
T4HMIN
3.5
dT1SH
3.6
dTSH
3.7
t_INTERVAL_H
3.8
T1SetH1
3.9
T1SetH2
3.10
T4H1
3.11
T4H2
3.12
ZONE1 H-EMISSION
3.13
ZONE2 H-EMISSION
3.14
FORCE DEFROST
4.1
T4AUTOCMIN
4.2
T4AUTOHMAX
5.1
WATER FLOW TEMP.
5.2
ROOM TEMP.
5.3
DOUBLE ZONE
6.1
ROOM THERMOSTAT
6.2
MODE SET PRIORITY
7.1
IBH FUNCTION
7.2
IBH LOCATE
7.3
dT1_IBH_ON
7.4
t_IBH_DELAY
7.5
T4_IBH_ON
7.6
P_IBH1
7.7
P_IBH2
7.8
AHS FUNCTION
7.9
AHS_PUMPI CONTROL
7.10
dT1_AHS_ON
7.11
t_AHS_DELAY
7.12
T4_AHS_ON
7.13
EnSWITCHPDC
State
The maximum ambient operating temperature for heating
mode
The minimum ambient operating temperature for heating
mode
The temperature difference between T1 and T1S(the
set water temperature) for starting the heat pump
The temperature difference between actual room
temperature Ta and the set room temperature Tas for
starting the heat pump
The start time interval of the compressor in heating mode
The setting temperature 1 of climate related curves for
heating mode
The setting temperature 2 of climate related curves for
heating mode
The ambient temperature 1 of climate related curves for
heating mode
The ambient temperature 2 of climate related curves for
heating mode
The terminal type of zone 1 for heating mode: 0=FCU(fan
coil unit), 1=RAD.(radiator), 2=FHL(floor heating loop)
The terminal type of zone 2 for heating mode: 0=FCU(fan
coil unit), 1=RAD.(radiator), 2=FHL(floor heating loop)
Enable or disable the FORCE DEFROST function:
0=NON,1=YES
The minimum operating ambient temperature for cooling in
auto mode
The maximum operating ambient temperature for heating
in auto mode
Enable or disable the WATER FLOW TEMP.:0=NON,1=YES
Enable or disable the ROOM TEMP.:0=NON,1=YES
Enable or disable the ROOM THERMOSTAT DOUBLE
ZONE:0=NON,1=YES
Room thermostat type : 0=NON,1=MODESET,2=ONE ZONE
3=DOUBLE ZONE
Select the priority mode in ROOM THERMOSTAT:
0=HEAT,1=COOL
Select the mode that IBH(BACKUP HEATER) can run:
0=HEAT+DHW,1=HEAT
The installation location of IBH(PIPE LOOP=0)
The temperature difference between T1S and T1 for
starting the backup heater.
The time that the compressor has run before starting the
first step backup heater.
The ambient temperature for starting the backup heater.
Power input of IBH1
Power input of IBH2
Enable or disable the AHS(AUXILIARY HEATING
SOURCE) function:0=NON,1=HEAT,2=HEAT+DHW
Select the pump operating status when only AHS runs:
0=RUN,1=NOT RUN
The temperature difference between T1S and T1B for
starting the auxiliary heating source
The time that the compressor has run before starting the
additional heating source
The ambient temperature for starting the additional heating
source
Enable or disable the function that heat pump and auxiliary
heating source switch automatically based on running cost:
0=NON,1=YES
49
Default
Unit
25
°C
°C
-15
5
°C
2
°C
5
min
35
°C
28
°C
-5
°C
°C
7
1
/
2
/
0
/
25
°C
17
°C
1
/
0
/
0
/
0
/
0
/
0(DHW=valid)
/
1(DHW=invalid)
0
/
5
°C
30
min
-5
°C
0
kW
0
kW
0
/
0
/
5
°C
30
min
-5
°C
0
/