3.4.4 Cleaning the extraction outlet
Sometimes, during operation or after repeated use of the unit, its extraction outlet
can get blocked. In this case, remove the plastic part of the extraction channel while
the appliance is switched off (the plug is disconnected from the power socket) and
clean it as well as the groove in the appliance foot, e.g. with a pick and/or
compressed air.
See the 5 images below: to do this, unscrew the 2 Phillips-socket screws (suitable
screwdriver included), then slide out the plastic element of the extraction outlet
together with the spigot. Install in the reverse order of removal.