IntelliChlor
SCG Power Center (IC20, IC40 IC60)
The IntelliChlor Power Center converts AC electrical current to a low-voltage DC electrical current which is
required to produce chlorine. The power supply is connected with the pool circulation pump electrical source so
that the IntelliChlor SCG only operates when the pool pump is on. The Power Center should be mounted
vertically on the wall up to fifteen (15) feet away from the IntelliChlor SCG. The Power Center contains the
transformer, fuse, connector to the cell and the AC electrical current wiring configuration with the DC electrical
current output cable to the IntelliChlor SCG. A fuse is mounted on circuit board inside the enclosure for
additional protection. There are no other controls or lights on the Power Center. For information about installing
and proper use of the Power Center, see the "IntelliChlor Power Center Installation Guide," (P/N 520590).
WARNING: CHLORINE GAS BUILDUP
CAN OCCUR WITH IMPROPER WIRING: To
reduce the risk of personal injury the IntelliChlor
SCG Power Center must be installed on and
wirded to the load side of the time clock,
electronically controlled switch, or relay load
side, so that it will receive power only when the
pool pump is on. Otherwise, dangerous chlorine
gas buildup can occur. The IntelliChlor SCG
should never be energized when the pool pump
is OFF and water is not flowing through the unit.
IntelliChlor SCG IC15 Power Supply
The IntelliChlor SCG IC15 Power Supply converts AC electrical current to a low-voltage AC electrical current
which is required to produce chlorine. The Power Supply should be connected with the pool circulation pump
electrical source so that the IntelliChlor SCG only operates when the pool pump is on. A 15 ft. cord connected
to the IC15 unit plugs into the Power Supply which plugs directly into a 110VAC outlet. The Power Supply can
be mounted vertically on the wall up to fifteen (15) feet away from the IntelliChlor SCG.. The Power Supply
contains the transformer, fuse (1.5 AMP 250 V, 3 AG), connector to the cell and the AC electrical cord with
plug. There are no other controls or lights on the Power Supply. The Power Supply must be connected to a
GFCI protected outlet.
WARNING: CHLORINE GAS BUILDUP
CAN OCCUR WITH IMPROPER WIRING: To
reduce the risk of personal injury the IntelliChlor
SCG Power Center must be installed on and
wirded to the load side of the time clock,
electronically controlled switch, or relay load
side, so that it will receive power only when the
pool pump is on. Otherwise, dangerous chlorine
gas buildup can occur. The IntelliChlor SCG
should never be energized when the pool pump
is OFF and water is not flowing through the unit.
IntelliChlor SCG Power Center (Model PC 100).
Used with IC20, IC40 IC60
IntelliChlor SCG IC15 External Power Supply
®
IntelliChlor
Salt Chlorine Generator Installation and User's Guide
CAUTION - Before plugging or
unplugging the IntelliChlor SCG to the
Power Center, first switch off the AC
power to the Power Center.
CAUTION - First
switch OFF AC power to
the Power Supply before
plugging or unplugging the
IntelliChlor IC15.
3