DC voltage measurement / V=
Set the appropriate range using the selector switch. Connect the black test lead to the "COM"
jack and the red test lead to the "V/Ω" jack. Connect test leads to the test object. Read off
measurement result from the display. The voltage polarity is also displayed.
Measurement range
600 mV
6 V
60 V
600 V
AC voltage measurement / V~
Set the appropriate range using the selector switch. Actuate the "SEL button" and select AC.
Connect the black test lead to the "COM" jack and the red test lead to the "V/Ω" jack. Connect
test leads to the test object. Read off measurement result from the display.
Measurement range
600 mV
6 V
60 V
600 V
Frequency range: 10 Hz - 1.2 kHz
20
2
Resolution
Input resistance
0.1 mV
>1000 MΩ
1 mV
10 mV
>10 MΩ
100 mV
Resolution
Input resistance
0.1 mV
>1000 MΩ
1 mV
10 mV
>10 MΩ
100 mV
Electrical energy may cause serious injuries!
Always wear personal protective equipment!
^ hazet.com • ] info@hazet.de
Operation
Overvoltage protection
250 Vrms
750 Vrms
Overvoltage protection
250 Vrms
750 Vrms
Accuracy
±0.7 % of the
measurement
range + 2 digit
Accuracy
±0.8 % of the
measurement
range + 3 digit