DC current measurement / A=
Set the appropriate range using the selector switch. Connect the black test lead to the
"COM" jack and the red test lead to the "mA" or "10 A" jack. Connect the test leads with
the test object and read off the measurement result from the display. The current direction
is indicated by the sign.
You must use the "10 A" jack when
measuring currents above 600 mA!
Measurement range
600 µA
6000 µA
60 mA
600 mA
10 A
In the 10 A range observe the maximum duty cycles!
AC current measurement / A~
Set the appropriate range using the selector switch. Actuate the "SEL" button and select
AC. Connect the black test lead to the "COM" jack and the red test lead to the "mA" or
"10 A" jack. Connect the test leads with the test object and read off the measurement
result from the display.
You must use the "10 A" jack when
measuring currents above 600 mA!
Measurement range
600 µA
6000 µA
60 mA
600 mA
10 A
Frequency range: 10 Hz - 1.2 kHz
; Güldenwerther Bahnhofstraße 25 - 29 • 42857 Remscheid • GERMANY
[ +49 (0) 21 91 / 7 92-0 • \ +49 (0) 21 91 / 7 92-375 • ^ hazet.de • ] info@hazet.de
2
Resolution
Overvoltage protection
0.1 µA
1 µA
600 mA/250 V
Self-resetting fuse
10 mA
100 µA
10 mA
10 A / 1000 V
Resolution
Overvoltage protection
0.1 µA
1 µA
600 mA/250 V
Self-resetting fuse
10 mA
100 µA
10 mA
10 A / 1000 V
Electrical energy may cause serious injuries!
Electrical energy may cause serious injuries!
HAZET-WERK Hermann Zerver GmbH & Co. KG
Always wear personal protective equipment!
Always wear personal protective equipment!
Operation
Accuracy
±1.2 % of the measurement
range + 3 digit
±2.0 % of the measurement
range + 10 digit
Accuracy
±1.5 % of the measurement
range + 3 digit
±3.0 % of the measurement
range + 10 digit
21