Descargar Imprimir esta página

Continuity Test - Hazet-Werk 2152-600 Manual De Instrucciones

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 75
Resistance measurement / Ω
Set the appropriate range using the selector switch. Connect the black test lead to the "COM"
jack and the red test lead to the "V/Ω" jack. Connect the test leads with the test object and
read off the measurement result from the display.
Measurement range
600 Ω
6 KΩ
60 KΩ
600 KΩ
6 MΩ
60 MΩ
Overvoltage protection: 250 V RMS
Off-load voltage: 1.2 V
Diode test
Set the selector switch to "
lead with the "COM" jack and the red test lead with the "V/Ω" jack. Connect the test leads
with the test object (red test lead = anode, black test lead = cathode). The forward voltage
is displayed.
Measurement range
Overvoltage protection: 250 V RMS
Off-load voltage: 3.2 V

Continuity test

Set to "
/
" using the selector switch. Actuate the "SEL" button. Connect the black test
lead to the "COM" jack and the red test lead to the "V/Ω" jack. Connect test leads to the test
circuit.
Measurement
Function
The integrated buzzer signals continuity less than 50 Ω
Off-load voltage: 1.0 V
22
2
Resolution
Accuracy
0.1 Ω
1 Ω
10 Ω
±1.2 % + 5 digit
100 Ω
1 KΩ
10 KΩ
± 2.0 % + 10 digit
/
". Actuate the "SEL" button x 2. Connect the black test
Resolution
Accuracy
1 mV
Forward voltage
Electrical energy may cause serious injuries!
Always wear personal protective equipment!
^ hazet.com • ] info@hazet.de
^ hazet.com • ] info@hazet.de
Operation

Publicidad

loading

Productos relacionados para Hazet-Werk 2152-600