32 • ENGLISH
Warning! Do not operate the inflator when the car
engine is running.
Note: Make sure that your 12 Volt accessory socket is live.
On some vehicles the accessory socket may only become
live when the ignition key is in the accessory position.
INSTALLING AND REMOVING THE BATTERY
PACK (Fig. D, E)
Note: For best results, make sure your battery pack is
fully charged.
To install the battery pack into the battery port (15), align
the battery pack with the rails inside the battery port
and slide it into the handle until the battery pack is firmly
seated in the tool and ensure that it does not disengage.
To remove the battery pack from the tool, press the
release button (22) and firmly pull the battery pack out of
the tool handle. Insert it into the charger as described in
the charger section of this manual.
SWITCHING ON (Fig. F, G)
Warning! Risk of Bursting. Do not leave unit
running unattended. Overinflation of tires and other items
could result in serious injury and property damage.
Note: When power is supplied to the inflator by 12V
vehicle connector, 20V MAX* batteryy, or AC cord the
LCD display (3) will remain on for approximately 10
minutes before the display shuts off/goes into sleep mode.
This occurs when the unit is not operating. To wake up
the system, the user will need to push the pressure mode
/ reset button (5). At this time the LCD will turn on and the
inflator is ready for use.
f Before switching your inflator on decided which power
source you will be using; 12V vehicle connector, AC
plug or a 20V MAX* battery pack.
f To use the 12V vehicle connector, or 20V MAX* battery
pack press the AC/DC power switch (1) located on the
front of the unit to DC.
f If using the 12V vehicle connector, always fully extend
the cord before each use.
- Connect the 12V vehicle connector (14) into your
vehicles 12V accessory socket.
To use the AC cord, press the AC/DC switch (1) located
on the front of the unit to AC.
f If using the AC cord (13), always fully extend the cord
before each use.
- Connect the AC plug (13) into either a wall outlet or
an approapriate sized extension cord that is plugged
into a wall outlet.
To turn on high-volume
The high-volume hose is meant to be used for objects that
hold large amounts of air, such as air mattresses, rafts,
and swimming pool floats.
Note: The high-volume mode DOES NOT have an auto
shut-off feature.
1. Attach the high-volume hose (7) to the high volume
pump inflator connection (12) as described in the
"High volume hose" section.
2. Insert the high-volume hose (7), or it's tapered nozzle
(8) into the object being inflated.
3. Press the high-volume side of the mode power switch
(2), indicated by the air mattress symbol.
4. To turn off, push the power switch to the center position.
To turn on high-pressure
The high-pressure hose is meant to be used for objects
that need more air pressure, such as tires and basketballs.
1. Remove the high-pressure hose (10) from the storage.
2. Attach a nozzle as described in the "Universal valve
adapter" section.
3. Insert the nozzle into the object being inflated.
Press the high-pressure side of the mode power
4.
switch (2), indicated by the tire symbol.
5. To turn off, push the power switch to the center position.
DEFLATE USING THE HIGH-VOLUME HOSE (Fig. H)
Warning! Beware of objects being ejected.
When deflating, large amounts of air will exit the high volume
pump inflator connection (12). Ensure the universal valve
adapter is not pointed at anyone or anything.
1. Remove the high-volume hose (7) from the storage location.
f Line up the hose end (23) with the high-volume
pump deflate connection (11). Then, firmly slide in
the hose so it is securly in place.
2. Insert the hose, or it's tapered nozzle (8) into the
object being deflated.
3. Press the high-volume side of the mode power
switch (2), as shown in (Fig. G), indicated by the air
mattress symbol.
4. To turn off, push the power switch to the center
position.
5. To remove the hose, twist the hose clockwise and
slide hose off.
SETTING THE AUTOMATIC SHUT-OFF PRESSURE
Note: The LCD will only show inflation pressures when the
inflator is being used. In both inflation and pump mode the
unit will show battery status.
1. To switch between the different units (psi, bar or kPa),
press the pressure mode button (5) until the required
units are displayed.
2. Press the - or + pressure setting buttons (4) until the
required pressure is displayed.
3. After 3 seconds the display will flash and return to a
reading of "0.0". This is normal.
4. Connect the universal valve adaptor and accessories,

Publicidad