Descargar Imprimir esta página

Testing And Commissioning - Key Automation RXME Instrucciones Y Advertencias Para Su Instalación Y Uso

Receptor radio

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 11
on the associated remote control, once released it opens. ATTENTION: any disturbances can open
the contact even if the remote control button is still pressed.
• Timer seconds: in this mode it is possible to set a time in seconds after which the relay contact
opens. By default, the timer has a setting of 30 seconds. ATTENTION: the timer is reloaded every time
an associated transmitter is pressed.
• Timer minutes: in this mode it is possible to set a time in minutes after which the relay contact opens.
By default, the timer has a setting of 30 minutes. ATTENTION: the timer is reloaded every time an
associated transmitter is pressed.
4.4.1 - RELAY 1 AND 2 CONFIGURATION PROCEDURE
PH.
DESCRIPTION
Press the S button of receiver. The LED R1 relating to relay
1 starts flashing, to switch to relay 2 press the S button,
1
then the LED R2 starts flashing. The LED (R1 or R2) of the
selected relay flashes according to the set mode:
FLASHES
1 Flash
2 Flashes
3 Flashes
4 Flashes
PH.
DESCRIPTION
Press the P button to change the desired operating mode.
2
Each time the P button is pressed again, the configuration
passes to the next mode in a cyclic manner.
Exit the configuration by repeatedly pressing the S button
3
until the LEDs go off.
4.4.2 - TIMERS SETTING
PH.
DESCRIPTION
While in timer mode (seconds or minutes) hold down the S
1
button for about 2 seconds and wait that the LED (R1 or R2)
to flash regularly (one flash per second).
Hold down the S button and count the number of flashes of the
LED you want to set as seconds or minutes. Example: count
2
5 LED flashes to set 5 seconds/minutes depending on the
previously selected mode.
Once you have counted the flashes you want to set, release
3
the S button.

5 - TESTING AND COMMISSIONING

The system may be put into operation after testing by a qualified technician, who must
perform the tests required by the relevant standards in relation to the risks present, to
check that the installation complies with the relevant regulatory requirements.
EXAMPLE
S ►
R1
MODE
BISTABLE
IMPULSIVE
SECONDS TIMER
MINUTES TIMER
EXAMPLE
P ►
+
R1
S
EXAMPLE
S ►
+
R1
S ►
+
R1
7

Publicidad

loading