Automatic safety off
Displaying power levels
Power Management
All manuals and user guides at all-guides.com
During the time extra power is activated, the power of other hotplates is limited. This is
indicated on the power display by intermittently showing the selected cooking level and
limited power.
Activating extra powerful setting
First select the hotplate by touching its relevant sensor:
▪ If the zone is at level "0"→ immediately after press the sensor (E) then press (B). Extra
powerful setting is on, and power indicator displays symbol "P".
▪ If the zone is set at any level (≠0)→ press (B), until "P" appears on the zone's display.
After 10 minute lapse the hotplate automatically switches to level 9.
Premature turning extra powerful setting off
Touch the desired hotplate sensor, and immediately after press the sensor (E). Letter "P"
disappears and the hotplate automatically switches to level 9.
If the power level is not changed during a preset time, the corresponding heater turns off
automatically. The maximum time a heater can stay on depends on the selected cooking
level. Uninterrupted operation at every power level of each cooking zone is limited in time.
When the cooking zone turns off by the safety mechanism, the display shows the symbol
"0" or "H", if there is residual heat.
The cooking zone can be turned off by the sensor (E) for setting the level cooking.
Level
Max. time on (hours)
Example:
Set the hotplate to power level 5 and let it operate for some time. If you don't change the
level, the safety mechanism will switch the hotplate off after 10 hours.
Protection against overheating
Induction cooktop is also fitted with safety device against overheating which protects
electronic parts from damages. This device operates on several levels. When cooking
zone's temperature increases excessively, the fan switches first. If this is not enough,
extra powerful heating is deactivated, and finally the safety device either reduces the
heating power of certain cooking zones or turns them off completely. When the hotplate
cools off, the full power of hotplate is again available. So during the operation you can
hear an steady hum due to the turning on of the cooling fan. It is possible that the cooling
fan continues to operate even after the cooktop turning off.
Power level 0:
A constant "0" is displayed on the heater display. If the induction generator indicates
residual heat, the display alternates between "0" and "H". This indication only disappears
when there is no longer any danger (at 50 °C).
The display shows a "0" as long as the temperature remains below 50 °C, whereas it
shows an "H" whenever the temperature exceeds 50 °C.
To save energy, turn off the burner in advance, in order to exploit the residual heat.
Power level 1...9, P:
If no pan is detected or if an aluminium pan is detected, the power level flashes on the
heater display. After 60 seconds, if a non-aluminium pan is not detected, the power level
returns to 0.
When a non-aluminium pan is detected, the power level is shown constant on the heater
display.
In cases where the cooktop is already in operation for some time, to change the
limit of power, before proceeding with the planning, unplug it, then reinsert the
plug after a couple of minutes.
The power drawn is 2800 W, but you can increase it at 3500 W, 6000 W or 7200W.
(This operation must be carried out by a qualified technician only).
24
1
2
3
4
5
6
10
10
10
10
10
10
7
8
9
10
10
3