Descargar Imprimir esta página

Weekly Cleaning En; Monthly Cleaning En; Quarterly Cleaning En; Troubleshooting - Abicor Binzel MFS-V2 Instructivo De Servicio

Ocultar thumbs Ver también para MFS-V2:

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 68
MFS-V2
9.1 Weekly cleaning
1 Unscrew the cable assembly on the machine side and bring it into a stretched position.
2 Unscrew retaining nut and pull out guide spiral liner or PA liner.
Risk of injury
Serious injuries caused by parts swirling around.
• When cleaning the wire guide with compressed air, wear suitable protective clothing, in particular
3 Clean wire feed hose from both sides with compressed air.
4 Slide adjusted guide spiral liner or PA liner into wire feed hose and secure with retaining nut.
9.2 Monthly cleaning
Oil all moving parts and roll bearing with suitable lubricating oil.
9.3 Quarterly cleaning
Check and clean both air filters in the E-Box, replace them, if necessary.

10 Troubleshooting

NOTE
• Some problems are listed below, with descriptions of possible causes and solutions. If the measures
• Please also consult the operating instructions for the welding components, such as power supply,
Fault
Cause
Unit is not
• Control or component defective
ready for
• Control switch S8 is not functiong or wrong setting
operation
• M-Drive safety switch not actuated
Wire is not fed • Motor defective (master or slave)
Motor control card fault: Fault cannot be eliminated
by pressing RESET trigger.
• When the wire feed trigger is pressed again, the
motor control card shows again a fault
Tab. 12
Troubleshooting

11 Dismounting

Dismounting may only be carried out by specialized personnel. Please make sure that the shutdown
procedures are strictly observed, before the dismounting work begins. Ensure this also for the components
integrated into the welding system.
WARNING
safety goggles.
described below are not successful, please consult your dealer or the manufacturer.
compressed air line.
Solution
• Replacement by specialized personnel
• Have skilled personnel check and adjust control switch
S8.
• Check by specialized personnel
• Switch unit to currentless state
• Change motor
• Press RESET trigger
• Replace feeding system or motor control card
• Replace feed motor or motor control card
• Wire fault in cable assembly or master drive
10 Troubleshooting
EN - 17

Publicidad

loading