Installing the Humidistat
1. Separate wallplate from humidistat.
CAUTION
Electrical Hazard
Can cause electrical shock or equipment damage. Disconnect power before beginning installation.
2. Mark the duct-tube hole. Hold the wallplate up to the desired location on the duct and make a mark inside
the duct tube hole.
3. Drill the duct-tube hole. Find your mark and drill a 1/2 in. hole in the duct. This is where the duct tube will
be inserted to capture air.
PULL HERE
Replace Batt
Replace Batt
Inside
Setting
%
%
HUMIDITY BOOST
Light
System
Next
Auto
M34565A
Fig. 10.
M34580A
Fig. 11.
M34581C
Fig. 12.
9
HE360 HUMIDIFIER
69-2631ES—13