SYSTEM MANAGEMENT FUNCTIONS
1. Deleting the entire code memory content (users)
2. Setting the master code
3. Memorising user codes locally
4. Memorising user codes remotely
5. Cancelling user codes locally
6. Cancelling user codes remotely
7. Activating the user code
8. DKSTPT transponder reader setup
9. DKSDUALT keypad setup
1. Deleting the entire code memory content (
- Press and hold down the P1 and P2 buttons for more than 4 seconds on the interface, buzzer B1 will beep.
- The led L1 will remain lit for the entire duration of the deletion, which lasts for about 3 seconds.
- The led L1 will flash for a few moments and then switch off and the buzzer B1 will beep. Release the buttons.
2. Setting the master code
Interface
- Move jumper J2 on the interface to 'position 2' then press and hold down the button P1 for at least 2 seconds.
- Buzzer B1 will beep and during the procedure leds L1 and L2 will flash slowly.
- The master code memorisation procedure will be activated with a time maximum of 30 seconds.
Keypad function
- Type the chosen numerical code into the keypad to enable access to the functions (max. 6 digits) and
press confirm " ". The interface will give confirmation by sounding a beep.
Transponder reader function
It is possible to memorise a maximum of 5 master transponder tags/cards to access the interface
remotely and manage user codes.
- On the interface, move the dips of 'S1' to 'ON' according to the table to select the memory locations.
- Move the tag near to the remote transponder reader, the interface will give confirmation by sounding a beep.
(*)
(*)
this procedure will also cancel any memorised RADIO codes).
(The master code allows the user codes to be managed remotely).
Important remarks
• In the interface STANDARD operating mode DKS codes do not need to be
memorised as they will be presented directly in output.
•
The maximum number of devices that can be connected to a single interface is limited
.
to three
( * )
If multiple DKSTPT or DKSDUALT devices are connected to the interface each of them must
be set up with different device addresses
23
.
dip 1 dip 2 dip 3 dip 4
ON
OFF
OFF
OFF
OFF
ON
OFF
OFF
OFF
OFF
ON
OFF
OFF
OFF
OFF
ON
ON
ON
ON
ON
If you have inserted an invalid master code
the interface will sound 5 consecutive beeps.
memory
location 1
location 2
location 3
location 4