7. Activating the user code
Keypad function
- Type the user code into the keypad and press " ".
- The keypad will sound a two-second long beep with the green led lit. The code has been accepted.
- Press A-B-C or D in the right hand column of the keypad (e.g. "C"). Activation successful.
Transponder reader function
- Move a tag containing the channel you wish to activate near to the transponder reader.
- The reader will sound a beep with the green led lit. Activation successful.
If you have inserted an invalid user code or a non memorised tag or card the interface will beep 3 times.
8. Setting the remote RFID reader DKSTPT (Dip 1, 2, 3 and 4)
To access the selection dips remove the electronic card protection panel.
dip 1 dip 2
Indicator modes
OFF OFF buzzer OFF - backlight OFF
OFF buzzer ON - backlight ON - event
ON
OFF
ON buzzer ON - backlight ON - low
ON
ON buzzer ON - backlight ON - high
9. Setting up the DKSDUALT keypad
Once the keypad has been installed, enter the service mode to set the operating parameters
To set the optional parameters type # password
The keypad will sound one 3-second long beep and the green led "L1" will flash quickly.
The service mode remains active for 20 seconds.
If the password is wrong the red led will flash quickly five times
The default password is 123456.
event: the indications are activated
(1)
when a tag / card is detected.
low: backlighting always active at
(2)
(1)
low intensity
(2)
backlighting always active at
high:
(3)
high intensity
(3)
on the keypad.
dip 3 dip 4
Device address
OFF
OFF 1st device address
ON
OFF 2nd device address
OFF
ON
3rd device address
26
If multiple DKSTPT or
DKSDUALT devices are
connected to the interface
each of them must be set
up with different device
addresses.