MENU
Enables or disables automatic closing
TCA
On: automatic closing enabled
Off: automatic closing disabled
Enables or disables condominium function.
On: condominium function enabled. The step-by-step impulse or transmitter impulse has no
IbL
effect during the opening phase.
Off: condominium function disabled.
Enables or disables rapid closing
On: rapid closing enabled. With the gate open or in the opening phase the intervention of the
SCL
photocell causes automatic closing after 3 s. Active only with TCA:ON.
Off: rapid closing disabled.
Selects the operating mode of the "Step by step button" and of the transmitter.
PP
On: Operation: OPEN > CLOSE > OPEN >
Off: Operation: OPEN > STOP > CLOSE > STOP >
Enables or disables pre-blinking.
PRE
On: Pre-blinking enabled. Blinking is activated 3s before the motor starts.
Off: Pre-blinking disabled.
The "service light" function is enabled or disabled on terminals (9-10)
On: output, enabled as "Service light". This output is activated at the beginning of each op-
SERL
eration and remains activated for the time preset by parameter TLS.
Off: output, enabled as "Open gate light".
This function is not enabled if the "2°Ch radio" logics is preset to ON.
The second radio channel is enabled or disabled on terminals (9-10).
On: "2
radio channel" output is enabled.
nd
2ch
Off: "2
radio channel" output is disabled. The output to terminals is activated as "Service
nd
light" if SERL=On, or as SCA if SERL=Off.
If this function is preset to On, any presetting of the SERL logics will be ignored.
The Step-by-Step and Pedestrian input modes is selected.
On: Input to terminal 18 activated as OPEN. Input to terminal 17 is activated as Closed.
OPCL
Off: Input to terminal 18 activated as Step-by-Step. Input to terminal 17 activated as Pedes-
trian.
The total reverse movement is enabled or disabled when the amperometric sensor is trig-
gered.
INVC
On: total reversion is enabled
Off: total reversion is disabled. The control unit controls a 2sec reversion and then locks the
gate leaves.
Start control signal to motors:
MINV
On: motor 2 starts first in the opening phase.
Off: motor 1 starts first in the opening phase.
It enables or disables reception of the transmitters duplicated by the "AK" series.
CVAR
On: AK transmitters reception enabled
Off: AK transmitters reception disabled.
The remote storage of the radio transmitter codes is enabled or disabled (see par. REMOTE
LEARNING).
REM
On: Enabled remote storage
Off: Disabled remote storage.
MENU
By selecting this function, the receiver awaits (Push) for a transmitter code to be assigned to the step-by-step function.
Press the transmitter key to be assigned to this function.
PP
If the code is valid, it is stored in memory and OK appears.
If the code is not valid, the wording Err is displayed.
By selecting this function, the receiver awaits (Push) for a transmitter code to be assigned to the second radio channel.
Press the transmitter key to be assigned to this function.
2Ch
If the code is valid, it is stored in memory and OK appears.
If the code is not valid, the wording Err is displayed.
If the 2CH logics is preset to OFF, the key assigned to 2CH function carries out the pedestrian control signal.
LOGICS (LOG)
FUNCTION
RADIO (RADi)
FUNCTION
MEMO
ON-OFF-(Default)
(ON)
(OFF)
(OFF)
(OFF)
(OFF)
OFF
(OFF)
(OFF)
(OFF)
(OFF)
(ON)
(ON)
15