By selecting this function, the receiver awaits (Push) for a transmitter code to be assigned to the PED function.
Press the transmitter key to be assigned to this function.
PED
If the code is valid, it is stored in memory and OK appears.
If the code is not valid, the wording Err is displayed.
ntx
By selecting this function the LCD screen shows the number of transmitters memorized into the receiver.
By selecting this function, the receiver awaits (Push) for a transmitter code to be erased from memory.
CLR
If the code is valid, it is erase and OK appears.
If the code is not valid or is not in memory, the wording Err is displayed.
RTR
Completely erase the receiver memory. Confirmation of operation is required.
Displays the number of complete cycles (open+close) carried out by the automation.
When the <PG> button is pressed for the first time, it displays the first 4 figures, the second time it shows the last 4. Example <PG> 0012 >>>
<PG> 3456: made 123.456 cycles.
This function enables to activate the maintenance request notice after a number of manoeuvres determined by the installer.
To activate and select the number of manoeuvres, proceed as follows:
Press button <PG>, the display will show OFF, which indicated that the function is disabled (default value).
With the buttons <+> and <-> select one of the numeric values proposed (from OFF to 100). The values are intended as hundreds of cycles of
manoeuvres (for example: the value 50 indicates 5000 manoeuvres).
Press the OK button to activate the function. The display will show the message PROG.
The maintenance request is indicated to the user by keeping the indicator lamp lit up for other 10 sec after the conclusion of the opening or clos-
ing operation.
RESET of the control unit. ATTENTION!: Returns the control unit to the default values.
Pressing the <PG> button for the first time causes blinking of the letters RES, pressing the <PG> button again resets the control unit. Note: The
transmitters are not erased from the receiver nor is the access password.
All the logics and all the parameters are brought back to default values, it is therefore necessary to repeat the autoset procedure.
Autoset of the control unit.
WARNING: during this operation, the gate leaves movement MUST be free from obstacles.
First pressure of the <PG> push-button causes the AUTO wording to flash at 1 sec intervals. If the <PG> push-button is pressed again, the au-
toset frequency of the control unit is carried out.
If the autoset sequence has a positive result, the wording "OK" appears on the display; conversely, the "Err" wording is displayed ( the autoset
should be repeated).
If, during the autoset sequence, any input is activated (PP,PED,PHOT,STOP), the procedure stops immediately and the wording "Err" is displa-
yed.
Note: The autoset presets the torque values of the motors. At the end of operation, check the correctness of the preset values and possibly
modify them by hand through the appropriate Menu.
It allows to type in an access protection code to the programming of the control unit.
A four-character alphanumeric code can be typed in by using the numbers from 0 to 9 and the letters A-B-C-D-E-F.
The default value is 0000 (four zeros) and shows the absence of a protection code.
While typing in the code, this operation can be cancelled at any moment by pressing keys + and – simultaneously. Once the password is typed
in, it is possible to act on the control unit by entering and exiting the programming mode for around 10 minutes in order to allow adjustments
and tests on functions.
By replacing the 0000 code with any other code, the protection of the control unit is enabled, thus preventing the access to any other menu. If a
protection code is to be typed in, proceed as follows:
- select the Code menu and press OK.
- the code 0000 is shown, also in the case a protection code has been previously typed in.
- the value of the flashing character can be changed with keys + and -.
- press OK to confirm the flashing character, then confirm the following one.
- after typing in the 4 characters, a confirmation message "CONF" appears.
- after a few seconds, the code 0000 appears again
- the previously stored protection code must be reconfirmed in order to avoid any accidental typing in.
If the code corresponds to the previous one, a confirmation message "OK" appears.
The control unit automatically exits the programming phase. To gain access to the Menus again, the stored protection code must be typed in.
IMPORTANT: TAKE NOTE of the protection code and KEEP IT IN A SAFE PLACE for future maintenance operations.
To remove a code from a protected control unit it is necessary to enter into programming with the password and bring the code back
to the 0000 default value.
IF YOU LOOSE THE CODE, PLEASE CONTACT THE AUTHORISED SERVICE CENTER FOR THE TOTAL RESET OF THE CONTROL UNIT.
16
CYCLES NUMBER (NMAN)
MAINTENANCE CYCLES (MACI)
RESET (RES)
AUTOSET (AUTO)
PASSWORD (CODE)