MAINTENANCE
Risk of severe injury or death by electrical shock, high temperatures, or
pressurized fluids.
• Always unplug the pump power cord in addition to removing the fuse or shutting off the circuit breaker before
working on the pump or switch.
• Let pump cool for a minimum of 2 hours before attempting to service. Submersible pumps can become pressur-
ized and hot under normal operating conditions.
Risk of damage to pump or other equipment.
• This unit is permanently lubricated. Oiling is not required. Do not open the sealed portion of the unit or remove
housing screws.
• Do not remove the motor housing cover, impeller, socket head cap screws, or seals. Warranty is void if the motor
housing cover, impeller, or seals have been removed. Repairs on the motor or impeller require special tools.
Storage
1. Unplug from the power source.
2. Disconnect the pump from the discharge plumbing.
3. Drain all liquid from the pump and allow to dry thoroughly.
4. Store the pump in a non-freezing area.

Periodic Service

Inspect and test the pump system condition and operation every three months — more frequently in
heavy use applications.
1. Check the power cords and electrical outlet for damage or corrosion.
IMPORTANT: If the power cord is damaged, the whole unit must be replaced.
2. Remove all debris (gravel, sand, floating debris, etc.) from the basin.
3. Check the pump system components (basin, pump, switch, etc.) for any build-up (sludge, sediment,
minerals, etc.) that would inhibit functionality of the components. If significant, remove build-up or
replace affected components.
4. Confirm that all flexible coupling hose clamps are fully tightened.
5. Refer to
"Operation" on page 6

Cleaning Impeller and Volute

1. Disconnect power to the pump.
2. Remove the eight screws that hold the base to the volute.
3. Separate the base from the volute.
IMPORTANT: Do not remove the motor housing cover.
4. Clean the impeller and the volute passage.
IMPORTANT: Do not use strong solvents on the impeller. Do not remove the impeller.
5. Be sure the impeller turns freely.
6. Reattach the base to the motor housing, securing it with the eight screws.
to test operation.
MAINTENANCE
Storage