All TRAPP multipurpose shredders,
✔
single-phase or three-phase, are assembled
with double voltage motors. They leave
factory without electrical connection to
allow the customer to choose the kind of
connection based on the voltage of their
property power source.
✔
To correctly make the connection, see data
shown on the motor plate and the number
printed on the insulation of the wires.
✔
For equipments sold without motor, the
choice of minimum output shall follow the
technical data shown on page 30.
Checking:
Before operating the equipment check:
That there are no tools or objects on the
✔
motor or on the equipment, principally
inside the grain, palm (cacti) or green
funnel.
If there is something obstructing the motor.
✔
If the rotation direction is correct.
✔
If the voltage of the power source is the
✔
same of that of the equipment.
32
Motor Installation
Operation Instructions
Attention!
Before making any connections, make
sure power source is disconnected.
1) Make sure the power source where
the equipment will be installed is
compatible with the data shown
on the motor plate.
2) Disconnect the power source to
make motor connections.
3) Make the connections shown
according to the voltage of the
power source.
4) Use insulating tape in the
connections done to protect them.
5) Make sure the connections are
well insulated.
6) Turn on power source and check
the rotation of the motor.
If there are people or objects near pulleys
✔
and belts.
If the equipment cover is properly closed.
✔
If the counter cutting blade is properly set
✔
and tightened (pg. 35).
Note:
If the equipment is properly prepared, start
the motor, allow it to reach maximum
revolution and start working.