Descargar Imprimir esta página

Champion Global Power Equipment CPG4000DHY-EU Manual Del Operador página 29

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 124
CPG4000DHY-EU - 3500W WIRELESS REMOTE START OPEN FRAME INVERTER
TROUBLESHOOTING
Problem
Engine will not start.
Engine starts but runs roughly.
Engine will not start wirelessly.
Engine will not start electrically.
Engine shuts down during operation.
Generator cannot supply enough power
or overheating.
Engine is running but no AC output.
Cause
No fuel.
Faulty spark plug.
Low oil level.
Spark plug wire loose.
Fuel valve is closed.
START/STOP button in "OFF" mode.
Old fuel or water in fuel.
Flooded with fuel.
Choke in the wrong position.
Dirty air filter.
Dirty fuel valve.
Clogged spark arrestor.
Remote control battery is dead.
Generator battery is dead.
START/STOP button in "OFF" mode.
Generator out of range of remote signal.
Obstructions in between generator and
remote.
Generator battery is dead.
START/STOP button in "OFF" mode.
Out of fuel.
Low oil level.
Clogged spark arrestor.
Generator is overloaded.
Dirty air filter.
Choke in wrong position.
Poor cord connection.
Circuit breaker is open.
Faulty inverter module.
Loose wiring.
AC Overload: Button illuminated red
Other.
29
TROUBLESHOOTING
Solution
Add fuel.
Clean and adjust spark plug or replace.
Fill crankcase to the proper level.
Place generator on a flat, level surface.
Attach wire to spark plug.
Open fuel valve.
Press START/STOP button to "STANDBY" mode
then again to "Start" or see manual start section.
Drain fuel and replace with fresh fuel.
Let unit stand for 10 mins.
Move choke until it stops under RUN position or
push choke button if illuminated green.
Clean or replace air filter.
Clean the fuel valve.
Clean spark arrestor.
Replace remote control battery.
Recharge generator battery.
Press START/STOP button to "STANDBY" mode
then press "START" one time on remote.
Remote must be with 80 feet of generator.
Clear line of site between generator and remote.
Recharge generator battery.
Press START/STOP button to "STANDBY" mode
then again to "START".
Fill fuel tank.
Fill crankcase to the proper level. Place generator
on a flat, level surface.
Clean spark arrestor.
Review load and adjust. See "Connecting
Electrical Loads."
Clean or replace air filter.
Move choke until it stops under RUN position or
push choke button if illuminated green.
Check all connections.
Reset circuit breaker.
Call Technical Support Team.
Inspect and tighten wiring connections.
Reduce AC load and press Overload Reset Button
until illuminated green.
Contact the help line.
EN

Publicidad

loading