Part Number
Model
Recommended battery bank *
Input
Voltage
Maximun current
Nominal Power
Efficiency
Input fuses
Output
Number of battery bank
rated current
Charging curve
Battery type
Boost voltage (default)
Floating voltage (default)
Regulation tolerance
Peak to peak ripple and noise
Automotive fuse
Environment
Cooling
Operating temperature
Storage temperature
Relative humidity
Casing
Length, height, depth) / Weight
Fixing center distance
Fixing screw (wall)
Protection factor
PCB protection
Standards
CE declaration of conformity
CE / EMC
CE / Security - Others
Protections
* Battery capacity recommended for lead type batteries, ratio C/10. Consult us for lithium batteries.
YPO48-12/40A YPO48-24/30A YPO48-36/20A YPO48-48/15A
48-12V/40A
48-24V/30A
300-500Ah
200-400Ah
40V-64V
40V-64V
15A
20A
570W
860W
2 x 20A /80V
2 x 20A /80V
40A
30A
IU or IUoU through internal push-button or CAN-BUS (Boost, Absorption, Floating and
Lead sealed as factory setting - Other choices through internal setting:
gel, AGM, Calcium Lead, Lithium, Stabilized power supply, etc.
14.4VDC
28.8VDC
13.8VDC
27.6VDC
3 x 20A /80V
2 x 20A /80V
From -20°C to +60°C, derating from 60°C. Above 65°Cswitch off
Water-repellent varnish (marine environment)
Polarity reversal, short-circuit, abnormal overheating
48-36V/20A
150-250Ah
40V-64V
20A
860W
96% typical
2 x 20A /80V
1
20A
Refresh – factory setting)
43,2VDC
41,4VDC
< 2% (at rated conditions)
< 2% (at rated conditions)
2 x 20A /80V
Natural (fanless)
From -40°C to +70°C
up to 70% (95% without condensation)
236 x 180 x 96 mm / 2.2kg
219 x 155 mm
4 off M5 round head screws
IP22
Available on request
EN61204-3
EN60335-2-29. Pending E-marking.
YPO48-48/30A
48-48V/15A
48-48V/30A
100-200Ah
200-400Ah
40V-64V
40V-64V
20A
30A
860W
1720W
2 x 20A /80V
2 x 20A /80V
15A
30A
57.6VDC
57.6VDC
52.2VDC
52.2VDC
2 x 20A /80V
2 x 20A /80V
50