GB
Gas Connection
WARNING: Before starting any work related with gas
installation, turn off gas supply. Risk of explosion.
Check if the appliance settings are compatible with the local distribu-
tion conditions (gas type and gas pressure) before placing the appliance.
Main gas pipe
Gasket
Hose entry record
Metal clamp
LPG connection hose
Main gas pipe
Gasket
Nut
Natural gas connection
hose
WARNING: All kinds of work to be performed on gas
equipment and systems should be carried out by au-
thorised and qualified persons.
WARNING: Do not move a gas connected appliance.
Any force may cause gas leakage as it may loosen the
hose.
For LPG connection, attach the metal clamp
to the hose coming from the LPG cylinder.
Install one end of the hose by pushing it all
the way to the hose inlet record on the back
of the appliance by heating it in boiling
water. And tighten with a screwdriver by
bringing the clamp to the end of the hose.
The hose and gasket inlet record required
for connection is as follows.
For natural gas connection, place the gas-
ket in the nut at the end of the natural gas
connection hose. Turn the nut to attach the
hose to the main gas pipe. Check for gas
leakage and complete the connection. The
hose and gasket inlet record required for
connection is as follows.