Safety Notes

Gloves should be worn during installation to prevent
crushing and cutting injuries.
The hot and cold supplies must be of equal pressures.

Installation Instructions

• Prior to installation, inspect the product for transport
damages. After it has been installed, no transport or
surface damage will be honoured.
• The pipes and the fixture must be installed, flushed
and tested as per the applicable standards.
• The plumbing codes applicable in the respective
countries must be observed.

Technical Data

Operating pressure:
Recommended operating pressure:
Test pressure:
Hot water temperature:
Thermal disinfection:
• The product is exclusively designed for drinking
water!
• Safety against backflow

Symbol description

Do not use silicone containing acetic acid!
Adjustment (see page 37)
To adjust the hot water limiter. Using a hot water limiter in
combination with a continuous flow water heater is not
recommended.
Dimensions (see page 40)
Fault
Mixer stiff
Mixer dripping
Water escaping at the threaded base - connection hoses not completely
Hot water temperature too low
4
max. 1 MPa
0,1 - 0,5 MPa
1,6 MPa
(1 MPa = 10 bar = 147 PSI)
max. 60°C
70°C / 4 min
Cause
- Cartridge defective, calcified
- Cartridge defective
screwed into basic body
- O-ring at the connection hose
defective.
- Hot water limiter incorrectly set
Assembly (see page 35)
English
Flow diagram (see page 40)
Spare parts (see page 38)
Special accessories (order as an extra)
Adapter (G⅜ / G½)
#93395000 (see page 38)
Cleaning (see page 41)
Maintenance (see page 42)
The check valves must be checked regularly according to
EN 806-5 in accordance with national or regional
regulations (at least once a year).
Operation (see page 42)
Hansgrohe recommends not to use as drinking water the
first half liter of water drawn in the morning or after a
prolonged period of non-use.
Test certificate (see page 44)
Remedy
- Exchange cartridge
- Exchange cartridge
- Tighten connection hoses by hand
- Exchange O-ring
- Set hot water limiter