Descargar Imprimir esta página

Gas Supply Requirements; Electrical Supply Requirements - Midea MGS30S2AST Instrucciones De Instalación

Ocultar thumbs Ver también para MGS30S2AST:

Publicidad

Idiomas disponibles

Idiomas disponibles

Gas Supply Requirements:

• Installation must conform with local codes or, in the absence of local
codes, with the National Fuel Gas Code, ANSI Z223.1/NFPA 54 or, in
Canada, the Natural Gas and Propane Installation Code, CSA B149.1
This product is equipped with a gas pressure regulator that operates at a
pressure of 5" of water column for operation with natural gas or 10" of
water column when converted for operation with LP (propane).
Make sure you are supplying your range with the type of gas for which it
is configured.
This range is convertible for use on natural or LP gas. When using this
range on LP gas, conversion must be made by a qualified LP installer
before attempting to operate the range.
For proper operation, the pressure of natural gas supplied to the regulator
must be between 5" and 13"of water column. For LP gas, the pressure
supplied to the regulator must be between 10" and 13" of water column.
When checking for correct operation of the regulator, the inlet pressure
must be at least 1" more than the operating (manifold) pressure as given
above.
The pressure regulator located at the inlet of the range must remain in the
supply line regardless of which type of gas is being used. A flexible metal
appliance connector used to connect the range to the gas supply line
should have an I.D. of 5/8" and a maximum length of 5 feet. In Canada,
flexible connectors must be single wall metal connectors less than 6 feet
in length.

Electrical Supply Requirements

• Installation must be electrically grounded in accordance with local
codes or, in the absence of local codes, with the National Electrical
Code, NFPA 70 or the Canadian Electric Code, CSA C22.1-02.
15

Publicidad

loading

Este manual también es adecuado para:

Mgs30s4ast