• Places where the connection cables have been cut
due to being driven over.
• Insulation damage due to being ripped out of the wall
outlet.
• Cracks due to the insulation ageing.
Such damaged electrical connection cables must not
be used and are life-threatening due to the insulation
damage.
Check the electrical connection cables for damage
regularly. Ensure that the connection cables are dis-
connected from electrical power when checking for
damage.
Electrical connection cables must comply with the ap-
plicable VDE and DIN provisions. Only use connection
cables of the same designation.
The printing of the type designation on the connection
cable is mandatory.
For single-phase AC motors, we recommend a fuse
rating of C 16A or K 16A for machines with a high start-
ing current (from 3000 watts)!
12. Cleaning
Danger!
Disconnect the mains plug before carrying out any
cleaning work.
• Keep protective devices, air vents and the motor
housing as free of dust and dirt as possible. Rub
the device clean with a clean cloth or blow it off with
compressed air at low pressure.
• We recommend that you clean the device directly
after every use.
• Clean the device at regular intervals using a damp
cloth and a little soft soap. Do not use any cleaning
products or solvents; they could attack the plastic
parts of the device. Make sure that no water can
penetrate the device interior. Water entering a power
tool will increase the risk of electric shock.
13. Transport
If you want to transport the device to a different loca-
tion, disconnect the device from the power supply and
set it down in another appropriate area.
34 | GB
14. Storage
Store the device and its accessories in a dark, dry and
frost-free place that is inaccessible to children. The op-
timum storage temperature lies between 5 and 30 ˚C.
Store the power tool in its original packaging. Cover the
power tool to protect it from dust or moisture. Store the
operating manual with the power tool.
15. Maintenance
Attention!
Disconnect the mains plug before carrying out any
maintenance work.
The device has no further internal parts that require
maintenance.
Service information
With this product, it is necessary to note that the follow-
ing parts are subject to natural or usage-related wear,
or that the following parts are required as consuma-
bles.
Wearing parts*: Abrasives, carbon brushes
* may not be included in the scope of supply!
Connections and repairs
Connections and repair work on the electrical equip-
ment may only be carried out by electricians.
Please provide the following information in the event
of any queries:
• Type of current for the motor
• Data of machine type plate
• Data of motor type plate
Spare parts and accessories can be obtained from our
service centre. To do this, scan the QR code on the
cover page.
16. Disposal and recycling
The device is supplied in packaging to avoid
transport damages. This packaging is raw ma-
terial and can thus be used again or can be
reintegrated into the raw material cycle.
The device and its accessories are made of
different materials, such as metals and plas-
tics. Take defective components to special waste dis-
posal sites. Check with your specialist dealer or munic-
ipal administration!