TIP:
· Do not connect with any electrical devices. (unload operation)
· Duration of the running engine depends on the amount of the fuel left in the tank.
· Remove the screws, and then remove the cover.
· Drain the fuel from the carburetor by loosening the drain screw on the carburetor float chamber.
· Turn the 3 in 1 switch to "OFF".
· Tighten the drain screw.
· Install the cover and tighten the screws.
· Turn the fuel tank cap air vent knob to "OFF" after the engine has completely cools down.
ENGINE
Perform the following steps to protect the cylinder, piston ring, etc. from corrosion.
· Remove the spark plug, pour about one table- spoon of SAE 10W-30 into the spark plug hole and reinstall the spark
plug. Recoil start the engine by turning over several times (with 3 in 1 switch knob off) to coat the cylinder walls with oil.
· Pull the recoil starter until you feel compression. Then stop pulling. (This prevents the cylinder and valves from rusting).
· Clean exterior of the generator. Store the generator in a dry, well-ventilated place, with the cover placed over it.
I
39