Descargar Imprimir esta página

Technical Data; Power Requirements - Truper SCI-14E Manual

Ocultar thumbs Ver también para SCI-14E:

Publicidad

Technical Data

Code
Description
Cutting Band
Cutting Capacity
Voltage
Frequency
Current
Power
Band Speed
Conductors
Work Cycle
Insulation
WARNING
Avoid the risk of electric shock or severe injury. When the power cable gets damaged
it should only be replaced by the manufacturer or at a
The build quality of the electric insulation is altered if spills or liquid gets into the tool while in use.
Do not expose to rain, liquids and/or dampness.
Before gaining access to the terminals all power sources should be disconnected.
WARNING

Power Requirements

WARNING
To prevent electric shock, the tool shall be grounded while
in use. • Connect the plug into a correctly grounded outlet as shown in
example A. Not all the outlets are properly grounded. If in doubt, verify with a
qualified electrician. • If the outlet where you will connect the tool has two
poles (2 orifices). UNDER ANY CIRCUMSTANCE, DO NOT REMOVE OR
ALTER THE PLUG'S GROUND CONNECTOR. Use a temporary adaptor as
shown in example B and always connect the ground conductor lug as shown.
CAUTION
When using an extension cable, verify the gauge is enough
for the power that the tool needs. A lower gauge cable will cause voltage drop
in the line, resulting in power loss and the motor will overheat. The following table shows the right size to use depending on cable's
length and the ampere capability shown in the tool's nameplate. When in doubt use the next higher gauge.
Ampere
Capacity
From 0 and up to 10 A
From 10 and up to 13 A
From 13 and up to 15 A
From 15 and up to 20 A
WARNING
When using power tools outdoors use a
Use". These extension cables are specially manufactured for outdoors use and reduce the risk of electric shock.
93 1/2" x 3/8" (4 tpi-teeth per inch)
127 V
8.8 A
1440 ft / min
14 AWG with 221 °F Insulation Temperature
120 minutes' work per 30 minutes' rest. Daily Maximum 6 hours
Power cord grips used in this product: Type "Y".
Tool build quality: Basic Insulation
Thermal insulation on motor winding: Class B
Number of
Conductors
From 6 ft to 49 ft
3 (one grounded)
SCI-14E
16458
Band Saw
14"
|
220 V
60 Hz
|
4.7 A
1 HP
2953 ft / min
Class I
Authorized Service Center.
CAUTION
Extension Gauge
|
Higher than 49 ft
18 AWG
16 AWG
14 AWG
8 AWG
grounded extension cable labeled "Outdoors
A
B
16 AWG
14 AWG
12 AWG
6 AWG
3
ENGLISH

Publicidad

loading

Este manual también es adecuado para:

16458