4. CONTROLS
Key
Key press
A
Short
Short
-
-
B
Short
Long press with
all loads off (mo-
tor and lights)
C
Short
Long press with
all loads off (mo-
tor and lights)
D
Long press with
light or motor on
E
Short
5. LIGHTING
• Please contact the Service Depart-
ment to change it ("Please contact
the service department to purchase
it").
10
Function
Turns the motor on/off at the first speed.
Turns the hood off at any speed.
Signals the Metal Grease Filters saturation alarm and the
need to wash them. The alarm is activated after 100 hours of effective
hood operation.
Signals the Activated Carbon Odour Filter saturation
alarm. The alarm is activated after 200 hours of effective hood oper-
ation.
Turns the motor on at the second speed.
Activates/Deactivates the Activated Carbon Filters alarm.
Turns the motor on at the third speed.
The Filters saturation alarm is reset.
Turns the motor on at the Intensive speed.
This speed is timed for 6 minutes. At the end of this time, the system
automatically returns to the previously selected speed. If activated
with the motor off, once the time has passed it switches to OFF mode.
Switches the lights on/off at maximum intensity.
LED
Fixed
-
Slow flashing with the
hood off.
Fast flashing with the
hood off.
LEDs A+B are on.
LED A flashes twice:
alarm activated.
LED A flashes once:
alarm deactivated.
LEDs A+C are on.
The LED flashes three
times.
LEDs A+D are on but
LED D is flashing, indic-
ating activation of the
function.
Fixed