WPE DIESEL GENERATORS
If battery fluid is low, the engine may fail to start because
too little electricity is reaching the starter motor. Always
keep the fluid level between the upper level and lower
level.
If too much battery fluid is applied, the fluid may spill and
corrode the surrounding parts. DO NOT over fill.
Batteries are only covered by a 1 year warranty from
original date of purchase.
Operating your generator
1. Warm up the engine without load for about 3 minutes.
2. Our generator is equipped with low oil warning
system. The engine will stop automatically in case
of low oil pressure or a lubrication oil shortage. The
engine will stop immediately if restarted without a
lubrication oil refill. To check the oil level and refill
3. Do not loosen or readjust either the engine speed
limiting bolt or fuel injection limiting bolt (They have
been factory set) otherwise performance and fuel
economy will be affected.
Check during operation
1. Any abnormal sound or vibration?
2. The engine misfiring or running rough.
3. What about the color of the exhaust gas? (Is it black
or too white?)
If you notice any of the above phenomenon, stop the
engine and consult your nearest dealer or contact
technical support on 44(0)1942 715 407.
AC Operation
1. Start the engine and make sure the 'GREEN' pilot
lamp turns on. If it does not, the filament may be
burnt out.
2. The speed of generator must reach rated speed
(lever at top).
3. Generator can load when the indicator of voltmeter
shows at 240±10% (50Hz) on the panel of control box.
4. Plug in the appliance.
WARNING
Do not start two or more machines simultaneously.
Start them one by one. Do not use floodlights
together with other machines.
5. Be sure that all pieces of equipment are in good
working condition before connecting them to the
generator.
6. If an appliance or piece of equipment begins to
operate abnormally, becomes sluggish, or stops
suddenly, turn off the generator immediately. Then
disconnect the appliance and examine it for signs of
malfunction.
7. If overloading of the circuit trips the AC circuit
protector, reduce the electrical load on the circuit,
and wait a few minutes before resuming operation .
8. If the LCD display voltmeter is too low or too high,
stop the machine and examine it for cause of fault.
Stopping the generator
1. DO NOT stop the generator when it is under load. It
will damage the generator.
2. Turn off the AC circuit breaker.
3. Leave the engine speed lever in the "RUN" position,
operate the engine without load for approx 3 minutes,
DO NOT stop the engine suddenly because this may
cause the temperature to rise abnormal and cause
the nozzle to damage and seize the engine.
4. Turn the ignition key anticlockwise to "OFF" position .
MAINTENANCE
Periodic check and maintenance are very important for
keeping the engine in good condition. Please read the
detailed description of operating manual for each part.
Shut off the engine before performing any maintenance.
If the engine must run, make sure the area is well
ventilated. The exhaust contains poisonous carbon
monoxide gas.
After the engine has been used, clean it immediately with
a cloth to prevent corrosion and remove sediment.
DAILY
Check oil level
Check and replenish fuel
Check for oil leakage
Battery Liquid
Air Cleaner
Check and tighten and engine parts if loose
FIRST 20 HOURS
Change oil
Clean Oil Filter
6
MAINTENANCE