Descargar Imprimir esta página

After Use - Holmatro DR200ST Manual

Ocultar thumbs Ver también para DR200ST:

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 60
EN
6.4

After use

6.4.1
Shut down and disconnect
Retract the plunger completely into the cylinder.
Disconnect the hydraulic hose(s) from the tool and the pump. Refer to chapter 5.3.
6.4.2
Inspection
Check the tool for completeness, oil leaks and damage. Do not use the tool if it leaks or is damaged
and contact the Holmatro dealer.
6.4.3
Cleaning and storage
Clean the equipment and the used accessories before storing them.
Clean the coupler(s).
Dry the equipment if it was used in wet conditions. Rub a light layer of WD-40 preservative oil on the
steel parts.
Store the equipment in a dry and well-ventilated area.
7
Troubleshooting
7.1
General
Consult the Holmatro dealer if the listed solutions do not give the desired result, or in case of other
problems. For malfunctions or repair, always specify the model and serial number of the equipment.
7.2
The couplers do not connect or disconnect
/i
Possible cause
There is pressure in the system.
The couplers are dirty on the front.
The tool and/or hose are under pressure. This can
happen due to temperature fluctuations during
storage and transport.
The female coupler is faulty.
The couplers are not placed properly in line with
each other for connecting.
The couplers are not properly placed in line with
each other for disconnecting.
The snap ring of the female coupler is blocked by
dirt.
7.3
The couplers do not stay connected
/i
Possible cause
The external ring jams during connecting.
28
Solution
Set the pump in its neutral/release position.
Clean the couplers.
Use the pressure relief tool to release the
pressure.
Have it repaired by a Holmatro Certified
Technician.
Position both couplers properly in line with each
other and press them together in one smooth
action.
Support and guide the male coupler when
disconnecting.
Check the snap ring of the female coupler and
clean it.
Solution
Hold the hose at the bending restriction during
connecting.
916.400.194_003
DR200(ST)

Publicidad

loading

Este manual también es adecuado para:

Dr200